FDTD Analysis of Dosimetry in Human Head Model for a Helical Antenna Portable Telephone(Special Issue on Recent Progress in Electromagnetic Compatibility Technology)
スポンサーリンク
概要
- 論文の詳細を見る
This paper presents a dosimetric analysis in an anatomically realistic human head model for a helical antenna portable telephone by using the finite-difference time-domain(FDTD)method. The head model, developed from magnetic resonance imaging(MRI)data of a Japanese adult head, consists of 530 thousand voxels, of 2mm dimensions, segmented into 15 tissue types. The helical antenna was modeled as a stack of dipoles and loops with an adequate relative weight, whose validity was confirmed by comparing the calculated near magnetic fields with published measured data. SARs are given both for the spatial peak value in the whole head and the averages in various major organs.
- 社団法人電子情報通信学会の論文
- 2000-03-25
著者
-
Wang J
Nagoya Inst. Technol. Nagoya‐shi Jpn
-
Wang Jianqing
The Department Of Computer Science And Engineering Graduate School Of Engineering Nagoya Institute O
-
Wang Jianqing
The Department Of Electrical And Computer Engineering Nagoya Institute Of Technology
-
Wang Jianqing
The Authors Are With The Department Of Electrical And Computer Engineering Nagoya Institute Of Techn
-
Fujiwara Osamu
The Department Of Computer Science And Engineering Graduate School Of Engineering Nagoya Institute O
-
Fujiwara O
Nagoya Inst. Of Technol. Nagoya Jpn
-
Fujiwara Osamu
The Department Of Electrical And Computer Engineering Nagoya Institute Of Technology
-
Fujiwara Osamu
The Department Of Electrical And Computer Engineering Of Nagoya Institute Of Technology
-
Fujiwara Osamu
The Faculty Of Engineering Nagoya Institute Of Technology
関連論文
- Uncertainty of the One-Gram Averaged Spatial Peak SAR in Human Head for Portable Telephones due to Average Procedures
- Localized Specific Absorption Rate in the Human Head in Metal-Framed Spectacles for 1.5 GHz hand-Held Mobile Telephones
- Absence of Mutagenic Effects of 2.45GHz Radiofrequency Exposure in Spleen, Liver, Brain, and Testis of lacZ-Transgenic Mouse Exposed in Utero
- Dosimetry Evaluation of a Whole Body Exposure Setup for Small Animal at 2.45 GHz(Regular section)
- Multi-Grid FDTD Calculation of Electromagnetic Absorption in the Human Head for 5 GHz Band Portable Terminals
- Analysis of Transient Electromagnetic Fields Radiated by Electrostatic Discharges
- A Noninvasive Method for Dielectric Property Measurement of Biological Tissues (Special Issue on Biological Effects of Electromagnetic Fields)
- FDTD Simulation of Shielding Effectiveness of Metal-Coated Plastics for Pulsed Electromagnetic Fields(Electromagnetic Compatibility(EMC))
- Special Issue on Measurements and Control of Electromagnetic interference
- Realizing Highly Localized Exposure in Small Animals with Absorbing Material Covered Holder to Test Biological Effects of 1.5 GHz Cellular Telephones (Electromagnetic Compatibility (EMC))
- A Simple Method for Predicting Common-Mode Radiation from a Cable Attached to a Conducting Enclosure
- A Novel Setup for Small Animal Exposure to Near Fields to Test Biological Effects of Cellular Telephones
- An Analytical Approach to Model Indirect Effect Caused by Electrostatic Discharge (Special Issue on Discharge and Electromagnetic Interference)
- 86. Pathophysiological Studies on the Tenesmus(1st report)
- FDTD Analysis of Dosimetry in Human Head Model for a Helical Antenna Portable Telephone(Special Issue on Recent Progress in Electromagnetic Compatibility Technology)
- Experimental Investigation of Noise Immunity Diagnosis for Battery Drived Circuit by Bulk Current Injection Test(Special Issue on Recent Progress in in Electromagnetic Compatibility Technology)
- Head Tissue Heterogeneity Required in Compurtational Dosimetry for Portable Telephones
- Computation of Potential Attenuation Process for Charged Human Body Using Numerical Inverse Laplace Transform
- Approximation of Surface-SAR in a Realistic Head Model for Microwave Exposure Using External Magnetic Near-Field
- Usefulness of Spherical Model of Human Head in SAR Calculation for UHF Plane-Wave Exposure
- Correlation between Spatial Distributions of Surface-SAR and Magnetic Near-Field in Realistic Head Model for Microwave Exposure (Special Section of Letters Selected from the '92 Fall Conference and the '93 Spring Conference)
- Reduction of Electromagnetic Absorption in the Human Head for Portable Telephones by a Ferrite Sheet Attachment
- Computation of SAR Inside Eyeball for 1.5-GHz Microwave Exposure Using Finite-Difference Time-Domain Technique (Special Issue on Biological Effects of Electromagnetic Fields)
- New Approaches for Measurement of Static Electricity toward Preventing ESD