Investigation of Sheath Flow Chambers for Flow Cytometers : Micro Machined Flow Chamber with Low Pressure Loss
スポンサーリンク
概要
- 論文の詳細を見る
A new type of sheath flow chamber with low pressure loss was developed using micro-machining. The chamber was formed by laminating three 100-μm-thick, photoetched, metal plates. The device uses sheath-flow geometry : particles in suspension, which enter the chamber via an axial specimen nozzle, are enveloped by a buffering sheath flow and transported to a square capillary tube with cross-section of 300 μm×300μm. Finite element viscous-flow analysis is used to examine the flow behavior in the quasi-two-dimensional passage configuration which produces the fluid-dynamic focusing flow. Experimental measurement showed a smooth constricted sheath flow, and pressure loss was reduced to one-tenth of that which occurs with conventional glass flow chambers.
- 一般社団法人日本機械学会の論文
- 1997-02-15
著者
-
Ohki Hiroshi
Power & Industrial Systems Kasado Administrative Division Hitachi Ltd.
-
Ohki Hiroshi
Department Of Chemistry Faculty Of Science Osaka University
-
Takagi T
Aisin Seiki Co. Ltd. Kariya‐shi Jpn
-
Takagi Takeo
Mechanical Engineering Research Laboratory Hitachi Ltd.
-
Yamazaki Isao
Mechanical Engineering Research Laboratory Hitachi Ltd.
-
Takagi T
Mechanical Engineering Research Laboratory Hitachi Ltd.
-
MIYAKE Ryo
Mechanical Engineering Research Laboratories, Hitachi, Ltd.
-
OHKI Hiroshi
Mechanical Engineering Research Laboratory, Hitachi, Ltd.
-
Miyake R
Hitachi Ltd. Tokyo Jpn
-
Miyake Ryo
Mechanical Engineering Research Laboratories Hitachi Ltd.
関連論文
- Non-Abelian Discrete Symmetries in Particle Physics
- Structural Analysis of High-Silica Ferrierite with Different Structure-Directing Agents by Solid-State NMR and Ab Initio Calculations
- Phase Transitions and Molecular Motions in Guanidinium-d_6 Trihalogenomercurates(II) [C(ND_2)_3]HgBr_3 and [C(ND_2)_3]HgI_3 as Investigated by Means of ^Br and ^I NQR and ^2H NMR
- Dynamic Property of H_2O in Layered VOPO_4・2H_2O Studied by Solid-State NMR
- Crystal Structure and Ionic Conduction Mechanism of AgHgSX (X=Br, I)
- Crystal Structure of High Temperature Phase and Ionic Conductivity Mechanism of CuHgSX (X=Cl, Br)
- New Anionic Conductor KSbF_4 with Fluorite Structure
- New Lithium Ion Conductor Li_3InBr_6 Studied by ^7Li NMR
- Cation Diffusion in MGaBr_4 (M = Li, Cu, and Ag) Studied by ^7Li, ^Cu, and ^Ga NMR, ^BrNQR, and Conductivity
- Micro-Liquid Handling Devices for Miniaturized Chemical Analysis Systems
- A Study on the Rotating Stall in Vaneless Diffusers of Centrifugal Fans (1st Report, Rotational Speeds of Stall Cells, Critical Inlet Flow Angle) : Fluids Engineering
- N-Terminal Amino Acid Sequences of 440 kDa Hemoglobins of the Deep-sea Tube Worms, Lamellibrachia sp. 1, Lamellibrachia sp. 2 and Slender vestimentifera gen. sp. 1 Evolutionary Relationship with Annelid Hemoglobins
- The Deep-Sea Tube Worm Hemoglobin : Subunit Structure and Phylogenetic Relationship with Annelid Hemoglobin : Biochemistry
- Experimental Study of Unsteady Flow Behind a Francis Turbine Runner Exit
- Nonintrusive Gas Pressure Measurement by Laser Induced Fluorescence from NO Molecules
- Flow Cytometric Analysis by Using Micro-Machined Flow Chamber
- Investigation of Sheath Flow Chambers for Flow Cytometers : Micro Machined Flow Chamber with Low Pressure Loss
- Three generation magnetized orbifold models(16th YKIS Conference Progress in Particle Physics 2008)
- Anomalies of discrete symmetries and string phenomenology(Summer Institute 2007)
- Rotational Speed Fluctuation and Internal Flow in a Variable-filling Fluid Coupling
- Phase Transition in Solid Adipic Acid
- Local Structure of Polyethylene Glycol-NaI Solid Polyelectrolyte as Studied by 13C and 23Na NMR.