バリストカルジオグラフィーに關する研究(第2報) : 先天性心疾患についてのバリスト法的觀察
スポンサーリンク
概要
- 論文の詳細を見る
By the use of ballistocardiograph of modified von Wittern's table which has natural frequency of 0.6 cps. and is capable of taking simultaneous two directional records, longitudinal and lateral or sagital records were taken on 6 cases with pulmonary stenosis, 6 cases with patent ductus arteriousus, 11 cases with atrial septal defect, 8 cases with ventricular septal defect and 5 cases with coarctation of the aorta, and these records were analysed from the view points of hemodynamics studied by right heart catheterization. Thus the following results were gained.1. Pulmonary stenosis : Longitudinal IJ_M showed a tendency to be decreased but Ra and IK/IJ ratio had a tendency to be decreased. In cases with elevated right ventricular pressure, as compared to those of low right ventricular pressure, the ratio of amplitude of lateral and sagital systolic wave complex to that of longitudinal IJ_M tended to be increased. There was also a tendency for R-I interval to be shortened and for R-J interval to be prolonged.2. Patent ductus arteriosus : Longitudinal IJ_M, Ra and JK/IJ ratio showed a tendency to be increased and HI/IJ ratio tended to be decreased. In cases with great shunt flow (shunt rate of more than 50%) and elevated pulmonary arterial pressure, lateral and sagital systolic wave complex showed a marked increase in the amplitude. R-J and R-K interval ahd a tendency to be shortened. On the other hand, they were prolonged in two post-oprative cases.3. Atrial septal defect : Longitudinal IJ_M and Ra showed a tendency to be decreased. In cases with high shunt rate and elevated right ventricular pressure, lateral and sagital systolic wave complex showed a increased amplitude. R-I and R-J interval tended to be shortened.4. Ventricular septal defect : Longitudinal IJ_M and Ra showed a tendency to be decreased. In cases with high shunt rate, there was an increase in amplitude of lateral and/or sagital systolic wave complex. The increase in the amplitude was slight in cases with right to left shunt.5. Coarctation of the aorta : Longitudinal IJ_M and HI/IJ ratio tended to be increased and in all cases JK/IJ ratio showed a marked decrease.6. In deseases with left to right shunt flow (patent ductus arteriosus, atrial septal defect and ventricular septal defect), there was a positive correlation between shunt rate and the ratio of resultant force vector of lateral and sagital component to longitudinal force vector.
- 社団法人日本循環器学会の論文
- 1959-08-20
著者
関連論文
- 59) Anoxiaに関する研究(第19回日本循環器學會總會)
- 192) 肺循環に關する研究(第8報) : 肺内氣相量及び血液相量に關する研究(第18回日本循環器學會總會)
- 191) 肺循環に關する研究(第7報) : 肺實質障碍に於ける心肺性動態(第18回日本循環器學會總會)
- 174) 僧帽瓣疾患に於ける心肺性動態(第18回日本循環器學會總會)
- 151) 心及び血管壓波形に關する研究(第1報)(第18回日本循環器學會總會)
- 142)肺循環に關する研究(第6報) : 各種心疾患に於ける心肺性動態(一般演説,第17回日本循環器學會總會)
- 慢性心房細動の直流除細動後, 静脈麻酔時合併症が原因となって死亡した1経験例 : 第47回日本循環器学会関東甲信越北陸地方会
- 78)バリストカルジオグラフィー(第6報)(第21回日本循環器學會總會)
- 13) 簡易型バリストのDynamic Calibration(第1回日本循環器學會關東地方會總會)
- 392,393) バリストカルヂオグラフィー : 第4報, 第5報 : I. von Wittern型テーブルの振動姿態に就て : II. ベクトル・バリストカルヂオグラフに就て(日本循環器學會第20回總會)
- 230) バリストカルヂオグラフィー(第2報)(第18回日本循環器學會總會)
- 77)バリストカルヂオグラフィー(一般演説,第17回日本循環器學會總會)
- バリストカルジオグラフィーに關する研究(第1報) : 簡易型バリストカルジオグラフィーにおける横木の研究 : 特に横木と脛骨との間の結合状態による影響について
- 13) 肺循環に關する研究(第16報) : 冠循環との關連について(第22回日本循環器學會總會(前半))
- 肺疾患のバリストカルジオグラム : 第21回日本循環器学会関東甲信越地方学会総会
- バリストカルジオグラフィーに關する研究(第2報) : 先天性心疾患についてのバリスト法的觀察
- バリストカルジオグラフィーに関する研究-1・2-
- 141)肺循環に關する研究(第5報) : P^法其の他による心搏出量測定(一般演説,第17回日本循環器學會總會)
- 140)肺循環に關する研究(第4報) : 肺血量(一般演説,第17回日本循環器學會總會)
- 追加(79)Electromagnetic typeによるBallistocardiogramの研究(第2報) : Pick up回路の理論的考察,一般演説,第17回日本循環器學會總會)