The spasticity is a problem on the recovery of hemiplegic patients caused by C.V.A.. Many technics and medicines are used clinically to reduce the spasticity. But the judgment whether they are effective or not must be made quite objectively and frequently before and after the treatment. To that purpose, it is desirable to measure the grade with instrument which has the following conditions, 1) high sensitivity 2) stability 3) reproductivity 4) easy applicability for the clinic Hither-to many methods to measure the resistance against the passive movement of muscle have been used, but few satisfied the above-mentioned conditions. We applied the semi-conductor straingage to measure it. Because it has 100 times high sensitivity compared with the usual metal-foil-straingage. Accordingly, we can decrease the amplification grade, so that the S/N ratio will be improved. In spite of the using the manual movement of the fore-arm of the testee, we recognized the satisfying stability, reproductivility and the objectivity owing to the reasonable structure of the instrument. The relative small size of the apparat does not give the patient any feel of tension, and also it's very handy. Our instrument consists of one pole and two metal arms, the proximal arm fix the upper-arm and the distal arm, attached the cantilever-beam which fit with the semi-conductor straingage, fix the forearm. The metallic-arm can be rotatable from 0° to 135° freely. A potentiometer is equipped to the axis. The electric signal from the cantilever-beam and the potentiometer are transmitted through the amplifier to the recorder. Using our instrument, we obtained same curve on repeating 50 times tests in the hemiplegic patient with spasticity. The same results were obtained even by different examiners. Therefore we had the confidence of its objectivity, stability and reproductivility. The curves of normal adults were almost flat and stay near the baseline. In the spastic patients, two types of curve observed, the one rose rapidly and then suddenly fell down according as the stretching. The another rose steadily in proportion to streching. In the former case, we observed clinically the clasp-knife phenomen.
- 社団法人日本リハビリテーション医学会の論文
- 1979-01-18
著者
-
山崎 亢吉
名鉄病院下呂分院
-
高橋 義浩
博道会館山病院附属館山リハセンター
-
塚田 厚志
豊田中央研究所
-
塚田 厚志
株式会社 豊田中央研究所
-
塚田 厚志
(株)豊田中央研究所
-
小島 泉
名古屋保健衛生大学リハビリテーション科
関連論文
- 超音波ドプラー法による末梢循環の研究, 特に冷水浴及びアルコール飲用との関係について : 日本循環器学会第31回東海 第10回北陸合同地方会
- 65. 温浴療法と末梢循環に関する研究, 特に超音波ドプラー法による抹消動脈血流量について(社会, 脳性麻痺, その他)(第7回リハビリテーション医学会総会)
- シリコン力変換素子を利用した燃焼圧センサ : ピエゾ抵抗効果のセンサへの応用
- G-1 水晶振動式角速度センサのモード結合解析(バルク波デバイス,口頭発表)
- 7. 南房総地区におけるリハビリテーション活動(呼吸・循環・その他)
- 開構造支持を持つSOI角速度センサ
- 水晶振動式角速度センサのモデル化と振動解析(超音波エレクトロニクス)
- 薄膜MI素子を用いた電源自立型道路鋲による車両検知
- 自動車エンジン用磁歪式トルクセンサ
- 自動車エンジン用磁歪式トルクセンサ
- 磁歪効果による磁気ヘッド型トルクセンサ
- ポリイミド基板上の積層型薄膜MI素子
- ポリイミド基板上の積層型薄膜MI素子
- 変位拡大機構による半導体マイクロ圧力スイッチ
- 半導体ひずみゲージをはりつけた片持梁式荷重計による筋伸展抵抗測定について
- 1. 脳卒中における痙縮測定に関する研究 : 半導体歪み計を利用する方法(痙性)(第13回日本リハビリテーション医学会総会)
- 38. 超音波ドプラー法による末梢循環の研究(脳卒中)(第10回日本リハビリテーション医学会総会)
- 79.超音波ドプラー法による末梢循環の研究(第2報) : とくに冷水浴および機能訓練との関係について(第9回リハビリテーション医学会総会)
- II.1-15.脳卒中後筋痙縮に対する温熱の影響について(第14回日本リハビリテーション医学会総会)(脳卒中II)
- 自動車エンジン用磁歪式トルクセンサ