高温鋼板水スプレー冷却時の冷却特性および熱伝達率
スポンサーリンク
概要
- 論文の詳細を見る
Water-spray cooling is widely applied to forced cooling of hot steel products. A number of problems, however, still remain to be solved, including heat transfer mechanism, cooling ability, the difference of heat transfer coefficient values between the upper and lower surfaces of a horizontally placed wide plate on which spray is impinged, the effect of scale deposit on heat transfer, and so on. In order to investigate heat transfer phenomena and cooling abilities of water-spray cooling, plate specimens of carbon steels with dimension of 22.5 to 51mm×550mm×1000mm, heated at about 630℃, have been water-sprayed. The main results obtaind are as follows : (1) In the water-spray cooling of the upper and lower surfaces of a horizontally placed specimen with the same water flux W, the value of the heat transfer coefficient α on the upper surface is higher than that on the lower surface in the region of test conditions. (2) The maximum values of α of the upper and lower surfaces exist in the surface temperature of about 200℃. (3) The following equation is applicable for describing the quantitative relation of specimen surface temperature θ_s [℃] and W[l/m^2・min] with α [kcal/m^2・h・℃]. α=A・W^<0.8>・10^<B・θ_s> where, A and B are constant.
- 社団法人日本鉄鋼協会の論文
- 1983-02-01
著者
関連論文
- ビレット用噴霧冷却設備の開発とその稼動実績
- 高温ビレットの噴霧冷却技術
- 羽口溶損機構に関する研究
- 有限要素-最小自乗法による熱伝導逆問題の解析
- 連続鋳造用ミスト冷却技術の開発
- 高温鋼板の浸漬冷却過程における沸騰現象および熱伝達に及ぼす水温の効果
- 高温鋼材水冷時の冷却能力に及ぼす水温の影響
- 高温鋼材水スプレー冷却時の表面温度 400〜800℃間での熱伝達率
- 高温鋼板水スプレー冷却時の冷却特性および熱伝達率
- 直交型気水ノズルから噴射される噴霧流の広がりおよび水量分布
- 高温鋼板フォグ冷却時の冷却特性および熱伝達率
- 高温鋼板浸漬冷却時の熱伝達現象および熱伝達に及ぼす攪拌の影響