As a forced-cooling method for hot steel products, air-atomized fog cooling is suitable for an intermediate cooling level between forced-air-cooling and water spray cooling. If conventional fog nozzles are used in steel processing lines, these nozzles will not be able to form proper fog for a long time, because small holes in these nozzles very often suffer clogging. Furthermore, there are serious problems of air economy and high level noise from high pressure atomizing. A newly improved fog nozzle enables water to be atomized with air under a pressure as low as 300 to 1000 mmH_2O. The feature of this nozzle is its simple design, a water pipe being attached to the end of a air pipe at right angles. One of the advantages of this nozzle is its capability of feeding water in a wide range of 0.1 to 10 1/min through a comparatively large water hole of inner diameter 3 to 6 mm. This report describes the design of this nozzle. The characteristics of a single fog stream from this nozzle are also shown, including atomization behavior and condition, fog spread, water distribtion in fog streams, influences of water and air pressures on atomization.