Preferred Illuminances on Surrounding Surfaces in Relation to Task Illuminance in Office Room Using Task-ambient Lighting
スポンサーリンク
概要
- 論文の詳細を見る
Comfortableness in various spaces is recently gaining priority. For comfortable lighting in a desk work area, visual comfort in the environment as well as good visual performance are required during a long desk work with visual tasks such as reading and writing documents.Preferable illuminance and luminance on surrounding surfaces in relation to the task (on the desk) illuminance should be determined appropriately.Since general lighting is usually used as office lighting, the previous paper clarified the preferred wall illuminance and luminance in relation to desk illuminance. On the other hand, task-ambient lighting has been proposed to save energy. In this paper, the following items are clarified with respect to the task-ambient lighting.(1) Preferred ambient illuminance in relation to task illuminance(2)Preferred wall illuminance in relation to task illuminance Further, with the use of task-ambient lighting based on the results above, even with energy-saving ambient illuminance, the ratio of consumed wattage per worker between general lighting and task-ambient lighting, is obtained through a simple calculation; the result reveald that the power saving amount to as much as 40-55%.
- 社団法人照明学会の論文
著者
-
MATSUSHIMA Koji
Matsushita Electric Works, Ltd.
-
Matsushima K
Univ. Tokyo Tokyo Jpn
-
TABUCHI Yoshihiko
Matsushita Electric Works, Ltd.
-
NAKAMURA Hajimu
Matsushita Electric Works, Ltd.
-
Nakamura Hajimu
Matsushita Electric Works Ltd
-
Nakamura Hajimu
Matsushita Electric Works Ltd.
-
Nakamura Hajimu
Engineering Center Matsushita Electric Works Ltd.
-
Tabuchi Yoshihiko
Matsushita Electric Works Ltd
-
Tabuchi Yoshihiko
Matsushita Electric Works Ltd.
関連論文
- Increased Expression of Interleukin-1β in Mouse Hippocampus after Global Cerebral Ischemia
- Morphological changes of c-Fos-like immunoreactivity in rat cerebral cortex after cerebral ischemia and reperfusion with special reference to vasoactive intestinal polypeptide
- Effect of focal cerebral ischemia on nitric oxide synthase expression in rats
- Indoor Lighting Facilities
- Neuropsychological Changes After Surgery for Anterior Communicating Artery Aneurysm
- Delayed neuronal cell death and microglial cell reactivity in the CA1 region of the rat hippocampus in the cardiac arrest model
- Fatal Severe Vasospasm Due to Rewarming Following Hypothermia
- Central Nervous System Metastases from Ewing's Sarcoma : Case Report
- Dissecting Aneurysm in the Proximal Region of the Posterior Inferior Cerebellar Artery Presenting as Wallenberg's Syndrome : Case Report
- Acute Subdural Hematoma Due to Near-Drowning : Case Report
- Preferred Illuminances on Surrounding Surfaces in Relation to Task Illuminance in Office Room Using Task-ambient Lighting
- A study on the estimation of the relative frequency of occurrences of the Clear Sky, the Intermediate Sky and the Overcast Sky in Japan
- Luminance distribution of Intermediate Sky
- Effect of Print Contrast on Reflected Glare
- Comparison of Glare Sensation from the Light Sources in the Central Vision and the Peripheral Vision
- Relationship between Illuminance/Color Temperature and Preference of Atmosphere