Comparison of Glare Sensation from the Light Sources in the Central Vision and the Peripheral Vision
スポンサーリンク
概要
- 論文の詳細を見る
Reduction of discomfort glare from a lighting installation is one of important factors for comfortable lighting. In a practical room, there are several light sources located at various positions. If an occupant look around room, he will see the light sources in both central and peripheral vision. Therefore it is important to establish criteria of discomfort glare effect for two or more sources in both central and peripheral positions. For the discussion on the criteria, the difference of the glare effects between central and peripheral visions needs to be clarified. However, the experiments in former studies are not sufficient for this purpose. Authours conducted an experimental study of subjective appraisal regarding the comparison of glare sensation from the light sources in the central vision and peripheral vision.Authours compared glare of light source in the central vision with each light source in the peripheral vision of upper side, right side and lower side location.The results are as follows : (1) Both source positions have similar slope in the equal-glare curve showing the relationship between source and background luminance.(2) As far as the glare effects from solid angle of a source, peripheral vision of right side and lower side source positions is similar to central vision, but peripheral vision of upper side source position is not similar.(3) The results regarding the peripheral vision of upper side source position, show some similarities to the study by Hopkinson and Bodmann.
- 社団法人照明学会の論文
著者
-
Nakamura Hajimu
Engineering Center Matsushita Electric Works Ltd.
-
Tabuchi Y
Matsushita Electric Works Ltd. Osaka Jpn
-
Tabuchi Yoshihiko
Engineering Center Matsushita Electric Works Ltd.
-
TSUTSUI Toru
Nagoya Engineering Center, Matsushita Electric Works, Ltd.
-
NISHIMURA Masanobu
Daido Institute of Technology
-
SATONE Hanji
Daido Institute of Technology
-
Tsutsui Toru
Nagoya Engineering Center Matsushita Electric Works Ltd.
-
Nishimura M
Daido Institute Of Technology
関連論文
- Preferred Illuminances on Surrounding Surfaces in Relation to Task Illuminance in Office Room Using Task-ambient Lighting
- A study on the estimation of the relative frequency of occurrences of the Clear Sky, the Intermediate Sky and the Overcast Sky in Japan
- Luminance distribution of Intermediate Sky
- Effect of Print Contrast on Reflected Glare
- Comparison of Glare Sensation from the Light Sources in the Central Vision and the Peripheral Vision
- Glare limitation of the fluorescent lamp luminaire with white diffuse reflector
- Relationship between Illuminance/Color Temperature and Preference of Atmosphere