Effect of the technique for assisting renal blood circulation on ischemic kidney in acute cardiorenal syndrome
スポンサーリンク
概要
- 論文の詳細を見る
- 2012-06-01
著者
-
Taenaka Yoshiyuki
国立循環器病センター研究所
-
Taenaka Yoshiyuki
国立循環器病センター研究所 人工臓器部
-
TAKEWA Yoshiaki
Department of Artificial Organs, Research Institute, National Cardiovascular Center
-
Tsukiya Tomonori
The Advanced Medical Engineering Center National Cardiovascular Center Research Institute
-
Tsukiya Tomonori
Department Of Artificial Organs National Cardiovascular Center Research Institute
-
Mizuno Toshihide
Department Of Artificial Organs Research Institute National Cardiovascular Center
-
Tatsumi Eisuke
Department Of Artificial Organs Research Institute National Cardiovascular Center
-
Taenaka Y
Department Of Artificial Organs Research Institute National Cardiovascular Center
-
Hamada Shigeru
Iwaki Co. Ltd.
-
Tatsumi Eisuke
Department Of Artificial Organs National Cerebral And Cardiovascular Center Research Institute
-
Taenaka Yoshiyuki
Department Of Artificial Organs National Cardiovascular Center
-
HANADA Shigeru
Department of Artificial Organs, Research Institute, National Cerebral and Cardiovascular Center
-
TAENAKA Yosiyuki
Department of Artificial Organs, Research Institute, National Cerebral and Cardiovascular Center
-
Tsukiya Tomonori
Department of Artificial Organs, Research Institute, National Cerebral and Cardiovascular Center
-
MIZUNO Toshihide
Department of Artificial Organ, National Cerebral and Cardiovascular Center
-
Taenaka Yoshiyuki
Department of Artificial Organ, National Cerebral and Cardiovascular Center
-
Takewa Yoshiaki
Department of Artificial Organ, National Cerebral and Cardiovascular Center
-
Tatsumi Eisuke
Department of Artificial Organ, National Cerebral and Cardiovascular Center
-
Tsukiya Tomonori
Department of Artificial Organ, National Cerebral and Cardiovascular Center
関連論文
- モノピボット遠心血液ポンプの開発と血液適合性評価
- 20317 補助循環用動圧浮上式血液ポンプの血液適合性評価(人工臓器と医用工学(4),OS.8 人工臓器と医用工学)
- 20316 ステップ動圧軸受の最適化による動圧浮上遠心ポンプの血液適合性改善(人工臓器と医用工学(4),OS.8 人工臓器と医用工学)
- 0404 連続流型補助人工心臓の耐久試験法に関する検討(OS22:機械式循環補助)
- 0403 体内埋込型補助人工心臓用軸流ポンプの生体適合性評価(OS22:機械式循環補助)
- 20307 表面粗さを付加した回転せん断負荷装置内の流動解析(人工臓器と医用工学(2),OS.8 人工臓器と医用工学)
- 20306 せん断流れ場において血液接触面の表面粗さが血球破壊に与える影響(人工臓器と医用工学(2),OS.8 人工臓器と医用工学)
- 回転型血液ポンプの流れの可視化
- Investigation of unifying transcutaneous transformer for transmission of energy and information
- Observation of cavitation pits on a mechanical heart valve surface in an artificial heart used in in vivo testing
- Effects of leaflet geometry on the flow field in three bileaflet valves when installed in a pneumatic ventricular assist device
- Improvement in magnetic field immunity of externally-coupled transcutaneous energy transmission system for a totally implantable artificial heart
- Development of a compact wearable pneumatic drive unit for a ventricular assist device
- Characteristics of cavitation intensity in a mechanical heart valve using a pulsatile device : synchronized analysis between visual images and pressure signals
- Oxygen metabolism during cardiopulmonary bypass with hemodilution using liposome-encapsulated hemoglobin in kid goats
- Up to 151 days of continuous animal perfusion with trivial heparin infusion by the application of a long-term durable antithrombogenic coating to a combination of a seal-less centrifugal pump and a diffusion membrane oxygenator
- Development of a compact portable driver for a pneumatic ventricular assist device
- Estimation of mechanical heart valve cavitation in a pneumatic ventricular assist device
- Mechanism for cavitation of monoleaflet and bileaflet valves in an artificial heart
- Monitoring of Diaphragm Position in Pulsatile Pnumatic Ventricular Assisted Device by Ultrasound Sensor : A New Method for Flow Measurement in VAD(Bioengineering)
- A Study on the Mechanism for Cavitation in the Mechanical Heart Valves with an Electrohydraulic Total Artificial Heart(Bioengineering)
- Observation of cavitation bubbles in monoleaflet mechanical heart valves
- Observation of alveolar fibrosis in a goat following venoarterial bypass for up to 5 months using extracorporeal membrane oxygenation
- Closing behavior of the mechanical heart valve in a total artificial heart
- Shear Evaluation by Quantitative Flow Visualization Near the Casing Surface of a Centrifugal Blood Pump(Reviewed Papers Accepted for Publication in this Special Issue)(Special Issue on Bioengineering)
- Proliferative changes in the media of the afferent arterioles under prolonged continuous-flow left heart bypass
- Analysis of specific absorption rate in biological tissue surrounding transcutaneous transformer for an artificial heart
- 1005 補助循環用動圧浮上式遠心ポンプの軸受隙間評価(OS2-(2) ライフサポートにおける工学技術,オーガナイズドセッション)
- Influence of varying conduit resistance on native heart function with nonpulsatile left heart bypass
- 1010 血液のせん断流れ場において金属材料表面粗さが溶血に及ぼす影響(OS2-(3) ライフサポートにおける工学技術,オーガナイズドセッション)
- Total Artificial Heart Control System by Using the Multiprocessors
- Effect of prolonged nonpulsatile left heart bypass on vascular control status
- 0401 機械的血液循環補助の技術動向(OS22:機械式循環補助)
- 1009 表面粗さを付加した回転せん断付加装置内の数値解析(OS2-(3) ライフサポートにおける工学技術,オーガナイズドセッション)
- Visualization of flow structure in a centrifugal blood pump impeller
- Current status of development and in vivo evaluation of the National Cardiovascular Center electrohydraulic total artificial heart system
- Aortic reaction to prolonged nonpulsatile left heart bypass
- Pivot wear of a centrifugal blood pump developed for circulatory assist
- Transient response of remnant atrial heart rate to step changes in total artificial heart output
- Flow visualization analysis of relative stagnation areas on the impeller surface of a centrifugal blood pump
- Observation of cavitation pits on mechanical heart valve surfaces in an artificial heart used in in vitro testing
- Radial-Type Self-Bearing Motor for Nonpulsatile-Type Artificial Heart
- Estimation of changes in dynamic hydraulic force in a magnetically suspended centrifugal blood pump with transient computational fluid dynamics analysis
- らせん流ポンプ内流れの可視化評価
- Journal of Artificial Organs 2010 : the year in review
- Journal of Artificial Organs 2009 : the year in review
- Journal of Artificial Organs 2008 : the year in review
- Journal of Artificial Organs 2007 : the year in review
- Initial in vivo evaluation of the newly developed axial flow turbo pump with hydrodynamic bearings
- A novel counterpulse drive mode of continuous-flow left ventricular assist devices can minimize intracircuit backward flow during pump weaning
- What is the ideal off-test trial for continuous-flow ventricular-assist-device explantation? Intracircuit back-flow analysis in a mock circulation model
- A novel counterpulsation mode of rotary left ventricular assist devices can enhance myocardial perfusion
- Neointima-inducing inflow cannula with titanium mesh for left ventricular assist device
- Computational fluid dynamic analysis of the flow field in the newly developed inflow cannula for a bridge-to-decision mechanical circulatory support
- Development and long-term in vivo testing of a novel skin-button system for preventing driveline infection of an implantable VAD system
- Journal of Artificial Organs 2011 : the year in review
- Effect of the technique for assisting renal blood circulation on ischemic kidney in acute cardiorenal syndrome
- Alteration of LV end-diastolic volume by controlling the power of the continuous-flow LVAD, so it is synchronized with cardiac beat : development of a native heart load control system (NHLCS)
- Flow visualization for different port angles of a pulsatile ventricular assist device
- Transcutaneous Optical Information Transmission System for a Totally-Implantable Artificial Heart : —Investigation of Full-Duplex Communication Using Same Wavelength—
- Change of Coronary Flow by Continuous-Flow Left Ventricular Assist Device With Cardiac Beat Synchronizing System (Native Heart Load Control System) in Acute Ischemic Heart Failure Model
- Catheter-related Bacteremia Caused by Agrobacterium radiobacter in a Hemodialysis Patient
- Change of Coronary Flow by Continuous-Flow Left Ventricular Assist Device With Cardiac Beat Synchronizing System (Native Heart Load Control System) in Acute Ischemic Heart Failure Model