Solidified Structure of S45C Steel with and without the Imposition of Electromagnetic Field
スポンサーリンク
概要
- 論文の詳細を見る
A S45C carbon steel has been solidified under the simultaneous imposition of a static magnetic field in vertical direction and an alternating current having a horizontal component. Thus, an electromagnetic force was excited in the sample and it affected structure formation during the solidification. The samples solidified under the different electromagnetic conditions were cut and chemically etched for the observation of the macro- and micro-structures. And those were compared each other. Without the imposition of the static magnetic field and the alternating current on the steel, micro-structure was dendrites. On the other hand, the solidified structure under the imposition of the 1 T static magnetic field and the alternating current of 80 A, 2 kHz was equi-axed structure. When the magnetic field intensity was decreased to 0.3 T, some parts of the solidified structure were equi-axed structure. As the frequency of the 80 A alternating current decreased under the constant magnetic field intensity of 1 T, the solidified structure changed from dendritic structure to equi-axed structure. Grain refinement mechanism is supposed to be breaking dendrites into pieces by convection induced in the sample by the non-uniform distribution of the electromagnetic force, which was intensified as the frequency of the electric current increased.
- 社団法人 日本鉄鋼協会の論文
- 2010-02-15
著者
-
IWAI Kazuhiko
Department of Materials Processing Engineering, Nagoya University
-
KOHAMA Takenori
Department of Materials, Physics and Energy Engineering, Nagoya University
-
Iwai Kazuhiko
Department Of Materials Physics And Energy Engineering Graduate School Of Engineering Nagoya Univers
-
Kohama Takenori
Department Of Materials Physics And Energy Engineering Graduate School Of Engineering Nagoya Univers
関連論文
- Structure Control of an Aluminum Alloy Using an Alternating Current Imposition during Its Pouring
- Characteristics of Liquid Metal Motion Driven by Quasi-sinusoidal Magnetic Fields
- Difference in Bioactivity, Initial Cell Attachment and Cell Morphology Observed on the Surface of Hydroxyapatite Ceramics with Controlled Orientation
- Analysis of Uniaxial Alignment Behavior of Nonmagnetic Materials under Static Magnetic Field with Sample Rotation
- Formation and biological affinity evaluation of crystallographically aligned hydroxyapatite( Ceramics for Biomedical Applications in Asian Countries)
- Copper Distribution in Fe–Cu and Fe–C–Cu Alloys under Imposition of an Intense Magnetic Field
- In-Situ Observation of Crystal Alignment under a Magnetic Field Using X-ray Diffraction
- Characterization of Surface Biocompatibility of Crystallographically Aligned Hydroxyapatite Fabricated Using Magnetic Field
- Crystal Alignment of Sn-Pb Alloy by Controlled Imposition of a Static Magnetic Field and an Alternating Electric Current during Solidification
- Orientation of Hydroxyapatite C-Axis under High Magnetic Field with Mold Rotation and Subsequent Sintering Process
- Formation of c-axis Aligned Polycrystal Hydroxyapatite Using High Magnetic Field with Mechanical Sample Rotation
- Plasma Behavior under Imposition of Alternating Magnetic Field Perpendicular or Parallel to the Plasma Arc Current
- Solidified Structure of S45C Steel with and without the Imposition of Electromagnetic Field
- Recent Progress of EPM in Steelmaking, Casting, and Solidification Processing
- Solidified Structure of Al Alloys by a Local Imposition of an Electromagnetic Oscillationg Force
- Copper Distribution in Fe-Cu and Fe-C-Cu Alloys under Imposition of an Intense Magnetic Field
- Quantification of Isothermal Phase Transformation in Solid Metals Based on Measurement of Magnetic Susceptibility
- Semi-continuous Magnetic Removal of Phosphate Using an Iron Oxide Hydroxide Adsorbent and Regeneration of Its Adsorbent
- Effect of Temperature Ranges of Alternating Current Imposition on Modification of Primary Mg_2Si Crystals in Hypereutectic Mg-Si Alloy
- Modification of Primary Mg_2Si Crystals in Hypereutectic Mg-Si Alloy by Application Alternating Current
- Effects of Operating Parameters on Modification of Primary Mg_2Si Crystals in Hypereutectic Mg-Si Alloy Treated by Imposition of Alternating Current
- Crystal Alignment of Sn-Pb Alloy by a Simultaneous Imposition of a DC Current and a Static Magnetic Field during Solidification
- Optimization of Alternating Current Imposing Period on Crystal Alignment of Sn-Pb Alloy Subjected to a Static Magnetic Field during Solidification
- Evaluation of Selective Separation of Phosphorous Components from Plating Baths Using Schwertmannite
- Structure of S45C Steel Solidified under the Simultaneous Imposition of a Static Magnetic Field and a Direct Current
- Crystal Alignment of Bi-Sn Alloy by Simultaneous Imposition of a Static Magnetic Field and an Alternating Current during Solidification
- Mechanism of Wave Excitation on a Liquid Metal Surface Submerged in an Intermittent Alternating Magnetic Field
- Free Surface Behavior of a Liquid Metal under the Imposition of a High Frequency Magnetic Field
- Generation of Compression Waves by Simultaneously Imposing a Static Magnetic Field and an Alternating Current and Its Use for Refinement of Solidified Structure
- Non-contact Generation of Compression Waves in a Liquid Metal by Imposing a High Frequency Electromagnetic Field
- Crystal Alignment of Titanium under Simultaneous Imposition of Electric Current and Magnetic Field
- Effect of Operating Parameters of an Electromagnetic Refining Process on the Solidified Structure
- Alignment Behavior of Bismuth Particles in Viscous Liquid under Imposition of Magnetic Field
- Alignment Behavior of Crystal with Magnetic Anisotropy of $\chi_{c} < \chi_{a}$ under Rotating Magnetic Field