Dependence of Attenuation of Common Mode Radiation from Indoor Power Line Communication System on Structure of Reinforced Concrete Wall
スポンサーリンク
概要
- 論文の詳細を見る
The attenuation effect of the walls of a building on the electromagnetic (EM) field generated by an indoor power line communication (PLC) system is numerically investigated using the finite integration (FI) method. In particular, we focus on the frequency range 2-6MHz, for which the attenuation effect has not yet been sufficiently analyzed. We model a single, finite-sized wall instead of an entire house, to focus on the dependence of the EM field on the wall structure and also reduce the computational resources required. The EM field strength is evaluated at many points on a view plane 10m from the wall model, and the results are statistically processed to determine the attenuation effect of the wall. We show that the leakage of an EM field at 2-6MHz is suppressed by about 30dB by a reinforced concrete wall. We also show that the main contributor to the attenuation effect is the rebar in the wall. We then investigate the relation between the attenuation effect of a single-wall model and that of a house model. The results show that the attenuation effect of a house model is almost the same as that of a 15-m-wall model. We conclude that the use of a single-wall model instead of a house model is effective in determining the attenuation of the EM leakage. This simple structure reduces analytic space, time, and memory in the evaluation of the dependence on the wall structure of the EM leakage from indoor PLC systems.
- (社)電子情報通信学会の論文
- 2009-09-01
著者
-
ISHIGAMI Shinobu
National Institue of Information and Communications Technology
-
Gotoh Kaoru
National Institute Of Information And Communications Technology
-
Ishigami Shinobu
National Institute Of Information And Communications Technology
-
MATSUMOTO Yasushi
National Institute of Information and Communications Technology
-
WU Ifong
National Institute of Information and Communications Technology
関連論文
- Multifractal Analysis for the ULF Geomagnetic Data during the Guam Earthquake
- A Study on Rise-time and Peak of the Transient Current Injected through Air Discharge of an ESD-gun
- APD Measurement for Evaluating Disturbances Related to the Performance of Digital Communication Systems(Communications, 2004 International Symposium on Electromagnetic Compatibility)
- Realistic FDTD Modeling of Contact Discharge with ESD-Gun for Electrostatic Discharge Testing
- A basic study on analysis of quasi-TEM waveguides using artificial magnetic conductors (環境電磁工学)
- A Method for Converting Amplitude Probability Distribution of Disturbance from One Measurement Frequency to Another
- Dependence of Attenuation of Common Mode Radiation from Indoor Power Line Communication System on Structure of Reinforced Concrete Wall
- Effects of Noise Radiation from LED Bulbs on Communications and Broadcasting Services