Optical Mouse Sensor for Non-Contact Tactile Sensing
スポンサーリンク
概要
- 論文の詳細を見る
Instead of functioning as part of a pointing device in computing, the optical mouse sensor is employed for non-contact tactile sensing in this study. The translation direction, the height and the category of an object surface can be sensed. It is an interesting idea to make an optical mouse sensor work in the manner of a human hand but in a non-contact way to “feel” the object surface. Based on the data table obtained from the experiments, the translation direction is calculated and the nonlinearity of the translation direction sensing is studied. It can be concluded that the resolution of an optical mouse sensor is direction-related. The feasibility of surface height measurement is analyzed and the optical mouse sensor can be used for crack detection on a plane surface. Height variation of 0.2mm can be detected. Besides, the feasibility of the optical mouse sensor for surface discrimination is proposed.
- 2008-09-01
著者
-
SHIDA Katsunori
Department of Advanced System Control Engineering, Graduate School of Saga University
-
Shida Katsunori
Department Of Advanced Systems Control Engineering Graduate School Of Science And Engineering Saga U
-
Wang Xin
Department Of Advanced Systems Control Engineering Graduate School Of Science And Engineering Saga U
-
Shida Katsunori
Department Of Advanced System Control Engineering Graduate School Of Saga University
-
Xin Wang
Department of Advanced Systems Control Engineering, Graduate School of Science and Engineering, Saga University
関連論文
- Organic field-effect transistors based on vapor-deposited pentacene and soluble pentacene precursor (第48回真空に関する連合講演会プロシーディングス--2007年11月14日〜16日,東京)
- Optical Mouse Sensor for Non-Contact Tactile Sensing
- A Novel Multifunctional Angular Position Sensor with Magnetic Fluid
- Resting Energy Expenditure and Substrate Metabolism in Chinese Patients with Acute or Chronic Hepatitis B or Liver Cirrhosis
- Effects of Ganoderma lucidum Polysaccharide on CYP2E1, CYP1A2 and CYP3A Activities in BCG-Immune Hepatic Injury in Rats(Pharmacology)
- Effects of Shikonin Isolated from Zicao on Lupus Nephritis in NZB/W F1 Mice
- Diagnosis and Treatment of VIPoma in China : (Case Report and 31 Cases Review) Diagnosis and Treatment of VIPoma
- Comparison of Selective Anterior Versus Posterior Screw Instrumentation in Lenke5C Adolescent Idiopathic Scoliosis
- New Contactless Inductive Sensor for the Measurement of Concentration of an Electrolytic Solution
- Estimation of Position and Relative Permittivity of Dielectric in a Cylindrical Air Condenser by New Capacitance Measurement Method