A New Isoelectric Focusing System for Fast Two-Dimensional Gel Electrophoresis Using a Low-Concentration Polyacrylamide Gel Supported by a Loose Multifilament String
スポンサーリンク
概要
- 論文の詳細を見る
- 日本分析化学会の論文
- 2004-12-10
著者
-
梅村 知也
Department Of Applied Chemistry Graduate School Of Engineering Nagoya University
-
Umemura Tomonari
Department Of Applied Chemistry Graduate School Of Engineering Nagoya University
-
TSUNODA Kin-ichi
Department of Chemistry and Chemical Biology, Gunma University
-
ODAKE Tamao
Department of Chemistry, Faculty of Engineering, Gunma University
-
LI Jinxiang
Department of Chemistry, Liaoning Normal University
-
OGASAWARA Ayaka
Department of Chemistry, Faculty of Engineering, Gunma University
-
小竹 玉緒
東大院・工
-
Li Jinxiang
Department Of Chemistry Liaoning Normal University
-
Ogasawara Ayaka
Department Of Chemistry Faculty Of Engineering Gunma University
-
Tsunoda Kin-ichi
Department Of Applied Chemistry Faculty Of Engineering Gunma University
-
Umemura T
Department Of Applied Chemistry Graduate School Of Engineering Nagoya University
関連論文
- Epidemiology of hepatocellular carcinoma in Japan
- Speciation of Human Serum Proteins Based on Trace Metal Mapping Analysis by CIM Monolithic Disk Column HPLC/ICP-MS in Complement with Off-Line MALDI-TOF-MS Analysis
- Chemical Speciation of Arsenic Species in Human Blood Serum by Liquid Chromatography Using a Phosphatidylcholine-Coated ODS Column with Detection by ICP-MS
- Assay of Alkaline Phosphatase in Salmon Egg Cell Cytoplasm with Fluorescence Detection of Enzymatic Activity and Zinc Detection by ICP-MS in Relation to Metallomics Research
- Speciation and Excretion Patterns of Arsenic Metabolites in Human Urine after Ingestion of Edible Seaweed, Hizikia fusiforme
- Identification of Aluminum Species in an Aluminum-accumulating Plant, Hydrangea (Hydrangea macrophylla), by Electrospray Ionization Mass Spectrometry
- Liquid Core Waveguide Spectrophotometry for the Sensitive Determination of Nitrite in River Water Samples
- Characteristics of a Liquid/Liquid Optical Waveguide Using Sheath Flow and Its Application to Detect Molecules at a Liquid/Liquid Interface
- インジウムスズオキサイド電極スラブ光導波路によるヨウ素の分光電気化学測定(ナノ空間と分析化学)
- A New Isoelectric Focusing System for Fast Two-Dimensional Gel Electrophoresis Using a Low-Concentration Polyacrylamide Gel Supported by a Loose Multifilament String
- 低屈折率高分子製光ファイバー型キャピラリーセルの特性とその鉄鋼試料中硫黄の吸 光光度定量への応用
- 光ファイバー型キャピラリーセルの分析化学における可能性 (特集 分析技術の進歩と話題)
- 微量元素のスペシエーション分析--ナノ分析化学への期待 (特集 極限に挑むナノ分析化学)
- 第6回分析化学東京シンポジウム・2002機器分析東京討論会
- 低屈折率高分子製光導波型キャピラリーセルの吸光セルとしての特性
- 光ファイバー型キャピラリーセルの分光分析への応用
- 新規多糖誘導体キラル固定相の開発とTLCへの応用
- 過マンガン酸カリウムによるフェノール系内分泌攪乱物質の分解
- Lock-in Modulation Detection for a Difference Interferometric Slab Optical-Waveguide Refractive-Index Sensor
- Determination of 56 Elements in Lake Baikal Water by High-Resolution ICP-MS with the Aid of a Tandem Preconcentration Method
- Evaluation of an ODS Column Modified with Zwitterionic/Nonionic Mixed Surfactants and Its Application to Direct Injection Determination of Inorganic Anions
- pH勾配固定化メッシュチューブゲルの作製とその二次元電気泳動システムへの適用
- An in-syringe La-coprecipitation Method for the Preconcentration of Oxo-anion Forming Elements in Seawater Prior to an ICP-MS Measurement
- Separation Characteristics of a Phosphatidylcholine-Coated ODS Column for Direct Sample Injection Analysis of Biological Fluid Samples
- Extracted Species of Rare Earth Elements Using Bis(1, 1, 3, 3-tetramethylbutyl)phosphinic Acid as an Extractant and Their Effective Mutual Separation by High-Performance Extraction Chromatography
- メッシュチューブを支持体に用いたタンパク質の等電点電気泳動用ゲルの開発と二次元ゲル電気泳動への応用
- 電極型光導波路を用いた分析法の可能性
- 糸を支持体とする一次元ゲルを用いるミニチュア二次元ゲル電気泳動システムの分離性能の評価と高分子量タンパク質の高速分離
- Identification of Al(III) Species in a Solution Containing Equimolar Concentrations of Al(III) and Citric Acid Using Varying-Temperature Al NMR Spectrometry
- Partitioning of Cations and Anions of Electrolytes in Electrostatic Ion Chromatography Using Pure Water as Mobile Phase
- Fractional Distributions of Trace Metals in Surface Water of Lake Biwa as Studied by Ultrafiltration and ICP-MS
- マイクロチップを用いたNO_2蛍光検出装置
- 多孔質ガラスを用いるガス吸収マイクロチップの試作と分析応用のための基本特性評価 (健康と分析化学)
- Rapid Reversed-phase Separation Using Methacrylate-based C18 Monolithic Capillary Columns at High Flow Rates and Elevated Temperatures
- Multielement Determination of Trace Metals in Seawater by Inductively Coupled Plasma Mass Spectrometry after Tandem Preconcentration Using a Chelating Resin
- Multielement Determination of Trace Metals in River Water (Certified Reference Material, JSAC 0301-1) by High Efficiency Nebulization ICP-MS after 100-fold Preconcentration with a Chelating Resin-Packed Minicolumn
- Highly Sensitive and Direct Detection of DNA Fragments Using a Laser-Induced Capillary Vibration Effect
- Fast Slab Gel Electrophoretic Separation of DNA Fragments with a Short Migration Distance Using Thermal Lens Microscope
- Decomposition of Phenolic Endocrine Disrupting Chemicals by Potassium Permanganate and γ-Ray Irradiation
- A case of well-differentiated cholangiolocellular carcinoma visualized with contrast-enhanced ultrasonography using Sonazoid
- Hepatitis B virus RNA is measurable in serum and can be a new marker for monitoring lamivudine therapy
- Speciation of Trace Elements, Binding and Non-binding with Proteins in Human Blood Serum, by Surfactant-Mediated HPLC with Element-Selective Detection by ICP-MS
- 電気泳動の高速マイクロ化--ミニチュアスラブゲル電気泳動装置の開発 (特集 ナノメカノテクノロジーと化学)
- Epidemiology of hepatocellular carcinoma in Japan
- A Slab optical Waveguide with a Thin Glass Guiding Layer as an Absorption Detector in Flow Analysis
- Extraction Chromatographic Behavior of Yttrium and Lanthanides in the Petroleum Sulfoxide-Ammonium Thiocyanate System
- Extractive Separation of Aluminum(III), Gallium(III)and Indium(III)Using Bis(1, 1, 3, 3-tetramethylbutyl)phosphinic Acid and Its Sulfur Analogues
- Miniaturized two-dimensional gel electrophoresis of high-molecular-weight proteins using low-concentration multifilament-supporting gel for isoelectric focusing
- Determination and Speciation of Aluminum in Soil Extracts by High-Performance Liquid Chromatography with Fluorescence Detection Using 5-Sulfo-8-quinolinol
- Separation of Zirconium(IV) and Hafnium(IV) by Extraction Chromatography Using Di(1-methylheptyl) Methylphosphonate as a Stationary Phase
- Sensitive Spectrophotometric Detection of Silicic Acid in Pure Water with Slab Optical Waveguide Absorption Detector
- Extraction Chromatographic Behaviors of Zirconium and Hafnium Using Sulfoxides as Stationary Phases
- Simultaneous Measurement System for an Adsorbed Substance on a Glass Slab Optical Waveguide and a Dissolved Substance in Liquid-Phase by Visible Absorption Spectrometry
- Fluorescent Derivatization of Nitrite Ions with 2, 3-Diaminonaphthalene Utilizing a pH Gradient in a Y-shaped Microchannel
- マイクロチップ技術による微量大気物質測定デバイスの開発 (2000年 第7回クロマトグラフィーシンポジウム--21世紀に向けた分離・検出科学の新展開) -- (セッション3 マイクロ化の新展開)
- Characteristics of Senosor Response of a Difference Interferometric Slab Optical Waveguide Refractive Index Sensor with a Prism Coupling Method
- Stability of Metal(II)-1, 1, 1-Trifluoro-mercapto-4-(2-thienyl)-3-butene-2-one-Nitrogeneous Base Ternary Complex on the Basis of HSAB Principle
- Aluminum in lake water and organs of a fish Tribolodon hakonensis in strongly acidic lakes with a high aluminum concentration
- Multielement Analysis of Commercial Mineral Waters by Chelating Resin Preconcentration and ICP-MS
- Speciation of Some Biometals in Salmon Egg Cell Cytoplasm by Two-Dimensional HPLC/ICP-MS
- Optical Waveguide Spectrometry for Steel Analysis and Its Related Area
- Distribution Behavior of Metal 4-(2-Thienyl)-4-thioxo-1, 1, 1-trifluoro-2-butanonates in Reversed-Phase High-Performance Liquid Chromatography
- Preparation and Characteristics of Pyridyl and 4,5-Dihydromidazolyl Groups Bonded Silica Gels as New Column Packing Materials for Separation of Metal Chelates by High Performance Liquid Chromatography
- A Grall Slab Optical Waveguide Detector with an Optical Position Sensor for Flow Analysis
- マイクロチップ技術による微量大気物質測定デバイスの開発
- New Determination Methods of Halides and Cyanide Ions by Electrospray Ionization Mass Spectrometry Based on Ternary Complex Formation
- Speciation of Trace Elements, Binding and Non-binding with Proteins in Human Blood Serum, by Surfactant-Mediated HPLC with Element-Selective Detection by ICP-MS
- Relative Enrichment of Mo in the Radicle of Peanut Seed (Arachis hypogaea), Observed by Multi-elemental Imagining with LA-ICP-MS
- Japanese tea leaves: A possible biological standard reference material.