Experimental Study on Surge Propagation Characteristics of Rail and Lightning Overvoltages on Level Crossing
スポンサーリンク
概要
- 論文の詳細を見る
Lightning protection measures are required for the railway signalling system because suspension and delays of trains due to lightnings may cause social confusion. Therefore, we carried out experiments on propagation characteristics of lightning surges along a rail, and injected a lightning surge current into the rail or wayside ground to raise their potentials, in order to measure the lightning overvoltages on a level crossing for the insulation design. There are no precedents that have carried out these experiments in the field until now. We could obtain the following results.(1) The surge impedance of the rail is 56Ω and the surge propagation velocity in the rail is 55m/μs.(2) The surge attenuation depends only on the duration of wave tail of the traveling lightning surge along the rail and decreases as the duration of wave tail becomes longer.(3) Flashovers may occur at the terminals in the equipment of the level crossing in case 1) a 2kA lightning surge current is directly injected into the rail, or 2) a 10kA lightning surge current is injected into the wayside ground at a vertical distance of 2m from the rail.(4) We can estimate the lightning overvoltages on the terminals in the equipment of the level crossing according to the vertical distance from the rail of the lighting stroke and the level of the stroke current.
- 社団法人 電気学会の論文
- 2003-11-01
著者
-
Sato Kazutoshi
Railway Technical Res. Inst. Kokubunji
-
Sato Kazutoshi
Railway Technical Research Institute
-
Arai Hideki
Komae Labs. Central Research Institute Of Electric Power Industry
-
MATSUBARA Hiroji
Komae Labs., Central Research Institute of electric Power Industry
-
MIYAJIMA Kiyotomi
Komae Labs., Central Research Institute of electric Power Industry
-
YOKOYAMA Shigeru
Komae Labs., Central Research Institute of Electric Power Industry
-
Yokoyama S
Criepi
-
Yokoyama Shigeru
Electric Power Engineering Research Lab. Central Research Institute Of Electric Power Industry
-
Miyajima Kiyotomi
Komae Labs. Central Research Institute Of Electric Power Industry
-
Matsubara Hiroji
Komae Labs. Central Research Institute Of Electric Power Industry
-
Yokoyama Shigeru
Komae Labs. Central Research Institute Of Electric Power Industry
関連論文
- A Simulation Study of Lightning Surge Characteristics of a Distribution Line Using the FDTD Method
- Experimental Study on Lightning Overvoltage Occurring on a Watthour Meter
- Toward development of distributed railway interlocking system (ディペンダブルコンピューティング)
- [4-1]Modeling and performance evaluation strategy of component-based distributed railway interlocking system(Report of 19th Autumnal Reliability Symposium)
- A development strategy for component-based distributed railway interlocking system
- Improving Reliability of Railway Interlocking System with Component-based Technology (特集 情報システムの信頼性・保全性)
- 4-1 Modeling and performance evaluation strategy of component-based distributed railway interlocking system
- A formal safety framework of component-based distributed railway interlocking system
- Effect of Lightning Protective Devices Attached to Pole Transformers on Reduction of Overvoltage on Distribution Lines
- Lightning Performance of Distribution Lines against Natural Lightning Strokes
- Analysis of Lightning Overvoltages in Low-Voltage Power Distribution Lines with Service Drop Lines
- Analysis of Lightning Overvoltages in Low-Voltage Power Distribution Lines with Service Drop Lines
- Lightning Protection Method of Power Distribution Lines Located in Mountainous Areas Facing the Sea of Japan
- Experimental Study on Short Circuit Phenomena in Air Switch of Distribution Line due to Sparkover between Different Poles on Which One Surge Arrester of the Three Ones is Omitted
- Experimental Study on Short-Circuit Inside an Air Switch of Power Distribution Lines due to Sparkover Between Different Poles
- Investigation on the Efficiency of Various Lightning Protection Systems for Wind Turbine Blades
- Voltage Distribution of Internal Windings of Pole-Mounted Distribution Transformer by Lightning Surge and Measures for Voltage Reduction
- Voltage Distribution of Internal Windings of Pole-Mounted Distribution Transformer When Lightning Surge Enters It and Measures for Voltage Reduction
- Analysis of the lightning surge propagating through a pole transformer on a real scale distribution line
- Experimental Study of Lightning Protection Design for Low Voltage Equipments
- Lightning Occurrence Data Observed with Lightning Location Systems of Electric Utilities in Japan : 1992-2001
- Lightning Occurrence Data Observed with Lightning Location Systems of Electric Utilities in Japan : 1992-2000
- Characteristics of Electromagnetic Fields due to Winter Lightning Stroke Current to a High Stack
- Outage Rates of Power Distribution Lines due to Summer and Winter Lightning in Chugoku Region
- Outage rates of Power distribution lines Due to Summer and Winter Lightning in the Chugoku Region
- Investigation of Overvoltage Phenomena due to Lightning Surge in Low Voltage Electric Wiring
- Experimental simulation lightning surge propagation through household equipment and damage mechanism
- Experimental Study on Lightning Damage of Wind Turbine Blades
- Estimation of Occurrence Probability of Lightning Damages on Railway Level crossing
- Estimation of occurrence probability of lightning damages on railway level crossing (特集 IWHV 2007 (5th International Workshop on High Voltage Engineering))
- Experimental Study on Surge Propagation Characteristics of Rail and Lightning Overvoltages on Level Crossing
- Experimental Study on Surge Propagation Characteristics of Rail and Lightning Overvoltages on Level Crossing System
- A Simulation Study of Lightning Surge Characteristics of a Distribution Line Using the FDTD Method
- An Investigation on Overhead Distribution-Line Modeling for Lightning Overvoltage Simulations
- Types of Winter Lightning Initiated by an Upward Leader from a 200m-high Stack
- Proposition of lightning protection design for low-voltage equipments
- Experimental examination of the freezing phenomena of the electric device by lightning surge
- Changes of the lightning damage aspect of electrical household appliances and electrical equipment
- Characteristics of Upward Leaders of Winter Lightning in the Coastal Area of the Sea of Japan