Experimental Study on Short Circuit Phenomena in Air Switch of Distribution Line due to Sparkover between Different Poles on Which One Surge Arrester of the Three Ones is Omitted
スポンサーリンク
概要
- 論文の詳細を見る
In this study, we experimentally examined the possibility of the internal short circuit of an air switch due to the sparkover between different poles under the condition that no surge arrester exists in neighboring poles and one of three surge arresters is omitted at the pole with an air switch. Experiments at Shiobara Testing Yard and Akagi Testing Center of CRIEPI clarified the following. Fault current may flow via the grounding point of a pole with an air switch and that of the next pole on a different phase from grounded phase of the pole with an air switch. If the low-voltage wire, overhead ground wire or communication wire forms a short circuit between them, ultimately the air switch may burn out. Moreover Fault current continues even if the length of the short-circuit between different poles is increased. Although the increase of the short-circuit length results in the increase of wire impedance, the amount of increase is still small compared with source impedance.
- 社団法人 電気学会の論文
- 2009-10-01
著者
-
YOKOYAMA Shigeru
Electric Power Engineering Research Lab., Central Research Institute of Electric Power Industry (CRI
-
Uemura Satoshi
System Engineering Research Lab. Central Research Institute Of Electric Power Industry
-
Yokoyama Shigeru
Central Res. Inst. Of Electric Power Ind.
-
ASAKAWA Akira
Central Research Institute of Electric Power Industry
-
SATO Tomoyuki
Electric Power Engineering Research Lab., Central Research Institute of Electric Power Industry
-
ASAKAWA Akira
Electric Power Engineering Research Lab., Central Research Institute of Electric Power Industry
-
HONDA Hideki
Tohoku Electric Power Co., Inc.
-
HORIKOSHI Kazuhiro
Research & Development, Center Tohoku Electric Power Co., Inc.
-
Honda Hideki
Tohoku Electric Power Co. Inc.
-
Sato Tomoyuki
Electric Power Engineering Research Lab. Central Research Institute Of Electric Power Industry
-
Asakawa Akira
Electric Power Engineering Research Lab. Central Research Institute Of Electric Power Industry
-
Honda H
Central Res. Inst. Electric Power Ind. (criepi) Kanagawa Jpn
-
Yokoyama S
Criepi
-
Yokoyama Shigeru
Electric Power Engineering Research Lab. Central Research Institute Of Electric Power Industry
-
Horikoshi Kazuhiro
Research & Development Center Tohoku Electric Power Co. Inc.
-
Yokoyama Shigeru
Electric Power Engineering Research Lab Criepi
関連論文
- A Simulation Study of Lightning Surge Characteristics of a Distribution Line Using the FDTD Method
- Simulation of Lightning-Induced Voltages on a Distribution Line Using the FDTD Method
- Experimental Study on Lightning Overvoltage Occurring on a Watthour Meter
- Effect of Lightning Protective Devices Attached to Pole Transformers on Reduction of Overvoltage on Distribution Lines
- Lightning Performance of Distribution Lines against Natural Lightning Strokes
- Analysis of Lightning Overvoltages in Low-Voltage Power Distribution Lines with Service Drop Lines
- Analysis of Lightning Overvoltages in Low-Voltage Power Distribution Lines with Service Drop Lines
- Lightning Protection Method of Power Distribution Lines Located in Mountainous Areas Facing the Sea of Japan
- Experimental Study on Short Circuit Phenomena in Air Switch of Distribution Line due to Sparkover between Different Poles on Which One Surge Arrester of the Three Ones is Omitted
- Experimental Study on Short-Circuit Inside an Air Switch of Power Distribution Lines due to Sparkover Between Different Poles
- Investigation on the Efficiency of Various Lightning Protection Systems for Wind Turbine Blades
- Voltage Distribution of Internal Windings of Pole-Mounted Distribution Transformer by Lightning Surge and Measures for Voltage Reduction
- Study on Lightning Protection Methods for Wind Turbine Blades
- Voltage Distribution of Internal Windings of Pole-Mounted Distribution Transformer When Lightning Surge Enters It and Measures for Voltage Reduction
- Analysis of the lightning surge propagating through a pole transformer on a real scale distribution line
- Experimental Study of Lightning Protection Design for Low Voltage Equipments
- Study of Lightning Electric Charge Amount Estimates Using Electric Field Measurements
- Lightning Occurrence Data Observed with Lightning Location Systems of Electric Utilities in Japan : 1992-2001
- Lightning Occurrence Data Observed with Lightning Location Systems of Electric Utilities in Japan : 1992-2000
- Characteristics of Electromagnetic Fields due to Winter Lightning Stroke Current to a High Stack
- Outage Rates of Power Distribution Lines due to Summer and Winter Lightning in Chugoku Region
- Outage rates of Power distribution lines Due to Summer and Winter Lightning in the Chugoku Region
- Analytical Study on Lightning Surge Characteristics of a Rail Track
- Investigation of Overvoltage Phenomena due to Lightning Surge in Low Voltage Electric Wiring
- Experimental simulation lightning surge propagation through household equipment and damage mechanism
- Experimental Study on Lightning Damage of Wind Turbine Blades
- Experimental Study on Surge Propagation Characteristics of Rail and Lightning Overvoltages on Level Crossing
- Experimental Study on Surge Propagation Characteristics of Rail and Lightning Overvoltages on Level Crossing System
- A Simulation Study of Lightning Surge Characteristics of a Distribution Line Using the FDTD Method
- An Investigation on Overhead Distribution-Line Modeling for Lightning Overvoltage Simulations
- Energy Absorption of Distribution Line Arresters due to Lightning Back Flow Current and Ground Potential Rise for Lightning Hit to Wind Turbine Generator System
- Risk evaluation of lightning damage to wind turbines with the electro-geometrical method (特集 IWHV 2007 (5th International Workshop on High Voltage Engineering))
- Types of Winter Lightning Initiated by an Upward Leader from a 200m-high Stack
- Investigation on Causes of Lightning Damages in Wind Turbine Blades
- Effect of Lightning Protective Devices Attached to Pole Transformers on Reduction of Overvoltage on Distribution Lines
- Development of Analysis Method for the Flashover Rate Due to Lightning on Power Distribution Lines in Consideration of Cost Performance
- Development of Analysis Method for the Flashover Rate Due to Lightning on Power Distribution Lines in Consideration of Cost Performance
- Effect of Impulse Waveforms on Lightning Attachment to an Open Wire and a Tree
- Discharge Characteristics to Insulated Material
- Observational Study of the Lightning Stroke Attraction Effect with Ground Wire System Constructions
- Observation of Current Characteristics of Winter Lightning at a 200m Chimney on the Coastal Area of the Sea of Japan from 2003 to 2005
- Observation of Winter Lightning at the Coast of the Japan Sea using a High-speed Video Camera
- Proposition of lightning protection design for low-voltage equipments
- Experimental examination of the freezing phenomena of the electric device by lightning surge
- Changes of the lightning damage aspect of electrical household appliances and electrical equipment
- Transient Grounding Characteristics of an Actual Wind Turbine Generator System at a Low-resistivity Site
- Characteristics of Upward Leaders of Winter Lightning in the Coastal Area of the Sea of Japan
- Study of Lightning Hazard Evaluation for Low Voltage Distribution Systems