Response Analysis of Radioactive Gas Monitors for Short Duration Inflow of Radioactive Gas
スポンサーリンク
概要
- 論文の詳細を見る
For accurate evaluation of gaseous activity released from nuclear facilities, proper calibration of radioactive gas monitors is required. Most of gas monitors are calibrated with a closed loop method. In this method, it is implicitly assumed that radioactive gases are statically released without rapid change of radioactivity concentration. However, actual radioactive gases are sometimes released in a short time-duration and with sudden change of radioactivity concentration. To confirm the applicability of the conventional closed loop method to such a kind of gas release, the responses of three typical gas monitors were analyzed in the manner of a pulse-like injection of a radioactive gas. The gaseous behavior in the sampling chamber of the monitors was evaluated from detailed observation of response curve. The gaseous activity injected pulse-like into the monitors was compared with that calculated from their response curves with the calibration factor determined by the closed loop method. These results show that the activity concentration in the sampling chamber becomes uniform as soon as the radioactive gas flows into the monitor. That is, the calibration factors determined by the closed loop method are applicable to both static and dynamic release.
- 一般社団法人 日本原子力学会の論文
- 2001-12-25
著者
-
大石 哲也
日本原子力研究所保健物理部
-
大石 哲也
(独)日本原子力研究開発機構
-
Oishi T
Japan Atomic Energy Research Institute
-
Oishi Tetsuya
Department Of Medicine Iii Okayama University Medical School
-
OISHI Tetsuya
Japan Atomic Energy Research Institute
-
YOSHIDA Makoto
Japan Atomic Energy Research Institute
関連論文
- IRPA-10印象記
- イメージングプレートを利用したエアフィルタの捕集性能の簡易評価法
- 緊急時環境モニタリングのための空気中プルトニウム放射能濃度測定装置の開発
- 表面汚染検査計の校正に使用するβ線面線源の均一性の評価
- 放射性ガスのパルス注入によるガスモニタの校正法
- 3E1116 降雨時の屋外環境中γ線量率の上昇に関する後方流跡線解析(2手法-3野外観測,一般研究発表)
- 緊急時における大気中α粒子モニタリング用フィルタの選定
- 若手研究会勉強会「放射線等に関する最近の出来事に関する考察」に参加して
- Crohn's Disease Associated with Growth Hormone Secretory Dysfunction
- Design of an Anti-Compton Spectrometer for Low-Level Radioactive Wastes using Monte Carlo Techniques
- Simulation of the Background for Gamma Detection System in the Indoor Environments of Concrete Buildings
- Japanese Family with Gloucocorticoid-Remediable Aldosteronism Diagnosed by Long-Polymerase Chain Reaction
- Hyperthyroidism in a Patient with TSH-Producing Pituitary Adenoma Coexisting with Thyroid Papillary Adenocarcinoma
- An EGS4 User Code Developed for Design and Optimization of Gamma-Ray Detection Systems
- Determination of Detection Efficiency Curve for a Gas Monitor with a Built-in Germanium Detector
- Determination of Gamma-ray Efficiency Cruves for Volume Samples by the Combination of Monte Carlo Simulations and Point Source Calibration
- Normotensive Bilateral Pheochromocytoma with Lindau Disease : Case Report
- Response Analysis of Radioactive Gas Monitors for Short Duration Inflow of Radioactive Gas
- An EGS4 User Code Developed for Design and Optimization of Gamma-Ray Detection Systems
- Dependence of Position Signal on Pressure of Counting Gas in Charge Division Type Position-Sensitive Proportional Counter.
- Preparation of Beta-ray Calibration Sources for Estimating Tissue Doses from Skin Contamination.
- モニタリングポストでの波高分布の時系列変化とプルーム中放射性核種に対する検出器応答を用いた I-131 濃度の推定