An EGS4 user code is developed to design and optimize gamma-ray detection systems for various types of radiation sources. The code is fundamentally based on the PRESTA-CG, which is the user code introducing the PRESTA algorithm and a combinatorial geometry method. The additional and existing functions are integrated in the present code, and the handling is simplified. The latest techniques related to the calculation of material cross section are also incorporated in the code for the accurate simulation. The main additional functions are classified into two parts of the definition of radiation sources and the photon tracing. The former includes the functions on the simple handling of source geometry and the use of redefined radiation source. In the latter functions, it is possible to estimate the simultaneous events among plural detectors and the trace of photon in the interested regions. The developed user code is applied to detection systems in order to demonstrate its availability. As the result, it is found that the present code allows the detailed response analysis of complicated detection systems for various radiation sources with a simple handling.
- 社団法人 日本原子力学会の論文
- 2003-06-25
著者
-
Sugita Takeshi
Science And System Laboratory
-
Oishi T
Japan Atomic Energy Research Institute
-
Oishi Tetsuya
Department Of Medicine Iii Okayama University Medical School
-
OISHI Tetsuya
Japan Atomic Energy Research Institute
-
TSUTSUMI Masahiro
Japan Atomic Energy Research Institute
-
YOSHIDA Makoto
Japan Atomic Energy Research Institute
-
Yoshida M
Japan Atomic Energy Research Institute
関連論文
- IRPA-10印象記
- イメージングプレートを利用したエアフィルタの捕集性能の簡易評価法
- 緊急時環境モニタリングのための空気中プルトニウム放射能濃度測定装置の開発
- 表面汚染検査計の校正に使用するβ線面線源の均一性の評価
- 放射性ガスのパルス注入によるガスモニタの校正法
- 緊急時における大気中α粒子モニタリング用フィルタの選定
- 若手研究会勉強会「放射線等に関する最近の出来事に関する考察」に参加して
- Crohn's Disease Associated with Growth Hormone Secretory Dysfunction
- Design of an Anti-Compton Spectrometer for Low-Level Radioactive Wastes using Monte Carlo Techniques
- Simulation of the Background for Gamma Detection System in the Indoor Environments of Concrete Buildings
- Japanese Family with Gloucocorticoid-Remediable Aldosteronism Diagnosed by Long-Polymerase Chain Reaction
- Hyperthyroidism in a Patient with TSH-Producing Pituitary Adenoma Coexisting with Thyroid Papillary Adenocarcinoma
- An EGS4 User Code Developed for Design and Optimization of Gamma-Ray Detection Systems
- Determination of Detection Efficiency Curve for a Gas Monitor with a Built-in Germanium Detector
- Determination of Gamma-ray Efficiency Cruves for Volume Samples by the Combination of Monte Carlo Simulations and Point Source Calibration
- A Novel Electron Beam-Induced Reaction of Sulfonium Salt in the Crystalline State
- Normotensive Bilateral Pheochromocytoma with Lindau Disease : Case Report
- Response Analysis of Radioactive Gas Monitors for Short Duration Inflow of Radioactive Gas
- A Novel Synthesis of 3-Thietanols by Reactions of 2-(1-Haloalkyl)oxiranes with Monothiocarbamic Acid Salts
- An EGS4 User Code Developed for Design and Optimization of Gamma-Ray Detection Systems
- Dependence of Position Signal on Pressure of Counting Gas in Charge Division Type Position-Sensitive Proportional Counter.
- Preparation of Beta-ray Calibration Sources for Estimating Tissue Doses from Skin Contamination.