Anatomically correct reduction and fixation of a Tile C-1 type unilateral sacroiliac disruption using a rod and pedicle screw system between the S1 vertebra and the ilium : experimental and clinical case report
スポンサーリンク
概要
- 論文の詳細を見る
- 2002-09-01
著者
-
Hisada Toshiaki
Graduate School of Frontier Sciences, The University of Tokyo
-
Tsutsumi Haruhiko
Advanced Tertiary Emergency Medical Center Saitama Medical Center Saitama Medical School
-
HIRABAYASHI SHIGERU
Department of Orthopaedic Surgery, Saitama Medical Center, Saitama Medical School
-
TSUZUKI NOBUYUKI
Department of Orthopaedic Surgery, Saitama Medical Center, Saitama Medical School
-
SAIKI Kunio
Department of Physics, Nagoya University
-
Hisada Toshiaki
Department Of Orthopaedic Surgery Saitama Medical Center Saitama Medical School
-
Saiki Kunio
Department Of Orthopaedic Surgery Saitama Medical Center Saitama Medical School
-
Shibuta Hideo
Department Of Rehabilitation Saitama Medical Center Saitama Medical School
-
HORIE TOSHIHIRO
Department of Orthopaedic Surgery, Saitama Medical Center, Saitama Medical School
-
INOKUCHI KOUICHI
Advanced Tertiary Emergency Medical Center, Saitama Medical Center, Saitama Medical School
-
Hirabayashi S
Department Of Orthopaedic Surgery Saitama Medical Center Saitama Medical School
-
Tsuzuki Nobuyuki
Department Of Orthopaedic Surgery Saitama Medical Center Saitama Medical School
-
Tsuzuki N
Saitama Medical School Saitama Jpn
-
Tsuzuki Nobuyuki
Department Of Orthopaedics Saitama Medical School Saitama Medical Center
-
Inokuchi Kouichi
Advanced Tertiary Emergency Medical Center Saitama Medical Center Saitama Medical School
-
Hirabayashi Shigeru
Department Of Dental Engineering Tsurumi University School Of Dental Medicine
-
Tsuzuki Nobuyuki
Department Of Orthopaedic Surgery Faculty Of Medicine University Of Tokyo.
-
Hirabayashi Shigeru
Department of Applied Chemistry, Faculty of Engineering, Niigata University
関連論文
- 1 Multi-physics, Multi-scale Simulator for Heart Research : Integration of Knowledge on Molecular Dynamics to Solve the Clinical Problems("State of the Art" Biomedical Technology Developed in Japan Will Inspire Intricate Applications in Cardiology in the
- Finite Element Analysis of Ventricular Wall Motion and Intra-Ventricular Blood Flow in Heart with Myocardial Infarction(Bioengineering)
- 1 Multi-physics, Multi-scale Simulator for Heart Research : Integration of Knowledge on Molecular Dynamics to Solve the Clinical Problems("State of the Art" Biomedical Technology Developed in Japan Will Inspire Intricate Applications in Cardiology in the
- Finite Element Analysis on the Relationship between Left Ventricular Pump Function and Fiber Structure within the Wall(Bioengineering)
- Computer Simulation of Blood Flow, Left Ventricular Wall Motion and Their Interrelationship by Fluid-Structure Interaction Finite Element Method(Reviewed Papers Accepted for Publication in this Special Issue)(Special Issue on Bioengineering)
- 1 Multi-physics, Multi-scale Simulator for Heart Research : Integration of Knowledge on Molecular Dynamics to Solve the Clinical Problems("State of the Art" Biomedical Technology Developed in Japan Will Inspire Intricate Applications in Cardiology in the
- 1 Multi-physics, Multi-scale Simulator for Heart Research : Integration of Knowledge on Molecular Dynamics to Solve the Clinical Problems("State of the Art" Biomedical Technology Developed in Japan Will Inspire Intricate Applications in Cardiology in the
- 1 Multi-physics, Multi-scale Simulator for Heart Research : Integration of Knowledge on Molecular Dynamics to Solve the Clinical Problems("State of the Art" Biomedical Technology Developed in Japan Will Inspire Intricate Applications in Cardiology in the
- PE-467 Virtual Echocardiography : A Realistic 3D Model of Blood Flow and Ventricular Wall Motion(Cardiac Function, Basic/Clinical 3 (M) : PE79)(Poster Session (English))
- PJ-601 Optical Mapping of Stretch Induced Ectopic Excitation and Spatial Strain Heterogeneity(Arrhythmia, basic-5 (A) PJ101,Poster Session (Japanese),The 70th Anniversary Annual Scientific Meeting of the Japanese Circulation Society)
- OE-239 The Effects of Wall Stress on the Dynamics of Ventricular Fibrillation : A Simulation Study Using a Dynamic Mechano-Electric Coupling Model(Arrhythmia, basic-1 (A) OE40,Oral Presentation (English),The 70th Anniversary Annual Scientific Meeting of t
- Pain and Rehabilitation in Patients with Spinal Cord Injury
- Long Results of Rehabilitation in Adults with Spina Bifida
- Clinical Effects of Capacitive Electric Transfer Hyperthermia Therapy for Cervico-Omo-Brachial Pain
- Changes in Range of Motion following Modified Open Bankart Procedure for Traumatic Anterior Instability of the Shoulder
- Pilot Study of ADL Score in Paraplegia with Spinal Cord Injury
- Correlations between Magnetic Resonance Imaging and Clinical Findings of Traumatic Incomplete Spinal Cord Injuries in the Chronic Stage
- Clinical Effects of Capacitive Electric Transfer Hyperthermia Therapy for Lumbago
- Functional Recovery and Prediction of Prognosis in Incomplete Spinal Cord Injured Persons
- A Technique for Studying Chemically Active Materials by Electron Microscopy
- Age-related changes in histogram pattern of anterior horn cells in human cervical spinal cord
- Surgical Treatment for Rheumatoid Forefoot Deformities by Complete Resection Arthroplasty of the Lesser Metatarsophalangeal Joints and Partial Syndactylization
- Sensitivity Analysis for Thermal Stress and Creep Problems
- Finite Element Analysis for Large Deformation Frictional Contact Problems with Finite Sliding
- Development of Sensitivity Analysis Code for Elastic-Plastic Dynamic Response of Piping Systems
- Electron Spin Resonance in Fine Particles of Metallic Lithium
- Surgical Anatomy of the Nerves and Muscles in the Posterior Cervical Spine : A Guide for Avoiding Inadvertent Nerve Injuries During the Posterior Approach
- Finite Element Analysis of Internal Fixation for Sacroiliac Joint in Pelvic Fractures
- Finite Element Analysis for Pelvic Fractures
- Spin-Reorientation and Antiferromagnetic Resonance in the Low Temperature Phase of Perovskite Crystal KMnF_3
- Equilibrium Spin Configuration and Antiferromagnetic Resonance of KMnF_3 at the Low Temperature Phase
- Occipitocervicothoracic fixation using a hook and rod system for patients with rheumatoid cervical spine
- Resonance Frequencies of Antiferromagnets Having Antisymmetric Exchange Interaction
- Anatomically correct reduction and fixation of a Tile C-1 type unilateral sacroiliac disruption using a rod and pedicle screw system between the S1 vertebra and the ilium : experimental and clinical case report
- Staged Spinal Cord Decompression Through Posterior Approach for Thoracic Myelopathy Caused by Ossification of Posterior Longitudinal Ligament
- Electron Spin Resonance of (KMnF_3)_x(KMgF_3)_
- Resonance Behaviour in Canted Antiferromagnet KMnF_3
- Contact of hydroxyapatite spacers with split spinous processes in double-door laminoplasty for cervical myelopathy
- New method for measuring area of spinal canal after double-door laminoplasty
- New method of assessing outcome of treatment for cervical myelopathy (M/T method) - preliminary report
- B-72. Electrospinogram (ESG) Evoked by Spinal Cord Stimulation
- A Homogenization Method for Nearly Incompressible Materials by Using Characteristic Deformation Mode Superposition
- SEM analysis of microstructure of adhesive interface between resin cement and dentin treated with self-etching primer
- Catalytic hydrogenolysis of 1,1-dichloro-3-methyl-2-phenylcyclopropane.