Ex-vivo Imaging of Thyroid Gland Using Ultrahigh-Resolution Optical Coherence Tomography at Wavelength from 800 to 1700 nm
スポンサーリンク
概要
- 論文の詳細を見る
Wavelength dependence of ex-vivo ultrahigh-resolution optical coherence tomography (UHR-OCT) imaging of thyroid gland using supercontinuum at wavelength from 800 to 1700 nm was demonstrated. The wavelength dependence of the thickness of follicular epithelium and fine structures such as round or oval follicles were observed from the UHR-OCT cross sectional images. The reconstructed en-face OCT images at all wavelength regions were obtained and the images of follicles with several different signal intensities were observed in 1060 and 1700 nm UHR-OCT images. To our knowledge, this is the first observation of wavelength dependence of OCT images of thyroid gland structure.
- 2012-03-25
著者
-
Ishida Shutaro
Department Of Electrical Engineering And Computer Science Nagoya University
-
Nishizawa Norihiko
Department Of Electrical Engineering And Computer Science Nagoya University
-
Nishizawa Norihiko
Department of Electrical Engineering and Computer Science, Nagoya University, Nagoya 464-8603, Japan
-
Ishida Shutaro
Department of Electrical Engineering and Computer Science, Nagoya University, Nagoya 464-8603, Japan
関連論文
- Octave Spanning High Quality Super Continuum Generation Using 10nJ and 104fs High Energy Ultrashort Soliton Pulse
- Squeezed Vacuum Generation Using Symmetric Nonlinear Polarization Interferometer : Optics and Quantum Electronics
- Nonlinear Polarization Interferometer for Photon-Number Squeezed Light Generation : Optics and Quantum Electronics
- Analysis of Generation Mechanism of Photon-Number Squeezed Light Using Ultrashort Pulse and Asymmetric Fiber Loop Mirror
- Characteristics of Intensity Noise Reduction of Optical Pulses Using Variabel Spectral Filters and Optical Fibers
- Three-Dimensional Optical Measurement with Spectroscopic Function Using Fiber Laser Supercontinuum
- Analysis of Effect of Chromatic Dispersion for Wavelength Tunable Ultrashort Soliton Pulse Generation
- Measurement of Timing Jitter in Wavelength Tunable Femtosecond Soliton Pulses
- Characteristics of Wavelength Tunable Femtosecond Soliton Pulse Generation Using Femtosecond Pump Laser and Polarization Maintaining Fiber
- Timing Jitter in Amplitude Modulated Harmonically Mode-Locked Er-Doped Fiber Ring Lasers
- Effect of Group-Velocity Dispersion on Photon-Number Squeezing of Optical Pulses using Optical Fibers and Spectral Filter
- Generation and Detection of Squeezed Light with Phase Tunable Fiber Loop Mirror using Polarization Beam Splitter
- Generation of Transform-Limited Pulse Train in New Scheme of Harmonically Mode-Locked Er-Doped Fiber Ring Lasers
- Effect of Guided Acoustic Wave Brillouin Scattering on Pulsed Squeezing in Optical Fibers with Nonlinearity and Dispersion
- Characteristics of Guided Acoustic Wave Brillouin Scattering in Polarization Maintaining Fibers
- Squeezed Light Generation with 1.064 μm Nd:YAG Laser and 0.85 μm Single-Mode Fiber
- Widely Wavelength Tunable Ultrashort Soliton Pulse and Anti-Stokes Pulse Generation for Wavelengths of 1.32-1.75 μm
- Ultrahigh-Resolution Optical Coherence Tomography in 1,7μm Region with Fiber Laser Supercontinuum in Low-Water-Absorption Samples
- Measurement of Chromatic Dispersion of Optical Fibers Using Wavelength-Tunable Soliton Pulses
- Analysis of Widely Wavelength Tunable Femtosecond Soliton Pulse Generation Using Optical Fibers
- Observation of Fine Lung Structure by Ultrahigh-Resolution Optical Coherence Tomography Using 800, 1060, and 1300 nm Supercontinua
- Subharmonic Synchronization of Picosecond Yb Fiber Laser to Picosecond Ti:Sapphire Laser for Stimulated Raman Scattering Microscopy
- Ex-vivo Imaging of Thyroid Gland Using Ultrahigh-Resolution Optical Coherence Tomography at Wavelength from 800 to 1700 nm
- Widely Broadened Super Continuum Generation Using Highly Nonlinear Dispersion Shifted Fibers and Femtosecond Fiber Laser
- Generation of Squeezed Vacuum Using Wavelength-Tunable Soliton Pulse and Nonlinear Polarization Interferometer
- Generation of Squeezed Vacuum using Spectral Filter by Spatial Light Modulator and Nonlinear Polarization Interferometer
- Optical-Fiber-Type Broadband Cavity Ring-Down Spectroscopy Using Wavelength-Tunable Ultrashort Pulsed Light
- High-Peak-Power Ultrashort Pulse Generation Using All-Fiber Chirped Pulse Amplification System with Small Core Multimode Fiber
- Generation of Widely and Flatly Broadened, Low-Noise and High-Coherence Supercontinuum in All-Fiber System
- Optical-Fiber-Type Broadband Cavity Ring-Down Spectroscopy Using Wavelength-Tunable Ultrashort Pulsed Light