We demonstrated the precise measurement of a 20-V programmable Josephson voltage standard (PJVS) system with an accuracy of $10^{-9}$. A 20-V PJVS chip including 524288 NbN/TiNx/NbN Josephson junctions (JJs) was used and operated in a cryocooler. By optimizing a microwave frequency, the widest current margin of a voltage step greater than 1 mA was obtained at 15.85 GHz. The maximum voltage of 17 V was also obtained at 18.00 GHz although we could not obtain voltages exceeding 20 V due to defective JJs. We also successfully compared the PJVS system with a 10-V Zener diode with an accuracy of $10^{-8}$.
- 2009-07-25
著者
-
Yamamori Hirotake
National Institute Of Advanced Industrial Science And Technology
-
Shoji Akira
National Institute Of Advanced Industrial Science And Technology
-
SASAKI Hitoshi
National Institute of Advanced Industrial Science and Technology
-
YAMADA Takahiro
National Institute of Advanced Industrial Science and Technology (AIST)
-
Shoji Akira
National Institute of Advanced Industrial Science and Technology, Tsukuba Central 2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568, Japan
-
Sasaki Hitoshi
National Institute of Advanced Industrial Science and Technology, Tsukuba Central 2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568, Japan
-
Yamamori Hirotake
National Institute of Advanced Industrial Science and Technology, Tsukuba Central 2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568, Japan
-
Yamada Takahiro
National Institute of Advanced Industrial Science and Technology, Tsukuba Central 2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568, Japan
関連論文
- Reduction in Shapiro Step Height in Double-Barrier Josephson Junction Arrays
- Structure and Dielectric Behavior of Epitaxially Grown SrTiO3 Film between YBa2Cu3O7-δ Electrodes
- Fabrication of High-Quality YBa_2Cu_3O_ Multilayer Structure Using Chemical Mechanical Planarization for Superconducting Quantum Interference Device Gradiometer
- Microwave Characteristics of NbN/NbN_x/NbN Josephson Junctions for Quantum Voltage Standards
- Development of a Thermal Voltage Converter With Calculable High-Frequency Characteristics
- Evaluation of Attenuation Constants of Superconducting NbN Coplanar Waveguides
- Precise Measurement of a 20-V Programmable Josephson Voltage Standard System
- NbN-Based Overdamped Josephson Junctions for Quantum Voltage Standards
- NbN-Based Overdamped Josephson Junctions for Quantum Voltage Standards
- Remote calibration of ionization chambers for radioactivity calibration
- Comparison between a 1-V NbN-Based Programmable and a Conventional Josephson Array
- Evaluation of Attenuation Constants of Superconducting NbN Coplanar Waveguides
- Reduction in Shapiro Step Height in Double-Barrier Josephson Junction Arrays
- Microwave Characteristics of NbN/NbNx/NbN Josephson Junctions for Quantum Voltage Standards