Measurement of a Linear Energy Transfer Distribution with Antioxidant Doped CR-39 Correcting for the Dip Angle Dependence of Track Formation Sensitivity
スポンサーリンク
概要
- 論文の詳細を見る
Antioxidant doped CR-39 detectors were loaded onto the STS-95 space shuttle mission (altitude: 574 km; inclination: 28.45°; flight duration: 8.9 days) for measuring the linear energy transfer (LET) distribution above 10 keV/μm for space radiation dosimetry. It is known that the track formation sensitivity of antioxidant doped CR-39 detectors depends on the dip angle of the incident particle. We investigated this dip angle dependence for a wide range of LET values and dip angles. The track formation sensitivities at lower dip angles were obviously decreased in the LET region below 100 keV/μm. We introduced minimum-cutoff dip angles in order to correct for such dip-angle dependence. The LET distribution of the STS-95 mission was obtained from the measurements of etch pits having dip angles larger than the minimum-cutoff dip angles. This new correction method increased the absorbed dose and dose equivalent above 10 keV/μm by 54 and 28%, respectively.
- 2008-09-25
著者
-
Masukawa Mitsuyo
Space Utilization Research Center National Space Development Agency Of Japan
-
Nagamatsu Aiko
Space Environment Utilization Center, Japan Aerospace Exploration Agency, 2-1-1 Sengen, Tsukuba, Ibaraki 305-8505, Japan
-
Tawara Hiroko
Radiation Science Center, High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801, Japan
-
Kitajo Keiichi
Space Station Engineering Department, Advanced Engineering Services Co., Ltd., 1-6-1 Takezono, Tsukuba, Ibaraki 305-0032, Japan
-
Kumagai Hidenori
Space Station Engineering Department, Advanced Engineering Services Co., Ltd., 1-6-1 Takezono, Tsukuba, Ibaraki 305-0032, Japan
-
Yasuda Nakahiro
Depertment of Technical Support and Development, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan
-
Masukawa Mitsuyo
Space Environment Utilization Center, Japan Aerospace Exploration Agency, 2-1-1 Sengen, Tsukuba, Ibaraki 305-8505, Japan
関連論文
- Closed water recirculating system for fish rearing equipped with bioreactor capable of simultaneous nitrification and denitrification
- Measurement of a Linear Energy Transfer Distribution with Antioxidant Doped CR-39 Correcting for the Dip Angle Dependence of Track Formation Sensitivity
- Dosimetry for Neutrons from 0.25 to 15 MeV by the Measurement of Linear Energy Transfer Distributions for Secondary Charged Particles in CR-39 Plastic