Calculation of Ozone Generation in AC Corona Discharge Reactor
スポンサーリンク
概要
- 論文の詳細を見る
The aim of this work is to study the analytical calculation of ozone generation in an ac corona discharge reactor. The corona discharges were generated in a dry air-fed wire-duct reactor stressed by an ac voltage at atmospheric pressure and room temperature. The current–voltage characteristics of the ac corona discharges relative to ozone generation in the reactor were measured under different discharge conditions. Subsequently, an empirical equation was derived for the calculation of the ozone concentration generated in the reactor on the bases of the experimental results. The derived equation can be used to predict the ozone concentration generated by ac corona discharges in the reactor for any values of the parameters that were investigated in the experiment.
- Published by the Japan Society of Applied Physics through the Institute of Pure and Applied Physicsの論文
- 2004-08-15