Low Voltage Pulse Application to Biological Cells
スポンサーリンク
概要
- 論文の詳細を見る
As an application of low electric field to biomedical engineering, this paper attempts to study the dose-effect of biological effects caused by msPEF with experiments on HeLa cells. MTT assay was used to trace the cell electroporation and examine cell viability. It is observed that with the increasing electric field intensity and pulse numbers, IRE effects will occur successively.
著者
-
Otsuka Hidenori
Department Of Applied Chemistry And Institute Of Colloid And Interface Science Science University Of
-
Matsuda Naoki
Measurement Solution Research Center Aist
-
Okabe Hirotaka
Measurement Solution Research Center National Institute Of Advanced Industrial Science And Technolog
-
OKIMURA Saya
Department of Applied Chemistry, Faculty of Science, Tokyo University of Science
-
NAGAMURA Masako
Department of Applied Chemistry, Faculty of Science, Tokyo University of Science
-
MATSUKUMA Daisuke
Department of Applied Chemistry, Faculty of Science, Tokyo University of Science
-
KUTSUZAWA Koichi
Department of Applied Chemistry, Faculty of Science, Tokyo University of Science
関連論文
- チトクロームcとITOの電子移動反応のその場観察(有機材料・一般)
- Two dimensionally aligned NHDF spheroid to create the three-dimensional skin equivalent
- Creation of High Performance Biocompatible Surface
- In Situ Observation of Time Dependent Electrochemical Activity of Cytochrome c at Bare Indium-Tin-Oxide Electrodes by Cyclic Voltammetry and Slab Optical Waveguide Spectroscopy
- Hepatocyte Spheroids Underlayered with Nonparenchymal Cells for Biomedical Applications
- In Situ Observation of Reduction Behavior of Cytochrome c Adsorbed on Glass Surface by Slab Optical Waveguide Spectroscopy
- Adsorption of a Single- or a Double-Chained Anionic Surfactant and Poly(vinylpyrrolidone) on Alumina from Their Binary Mixtures
- Direct Electrochemistry of Hemoglobin Molecules Adsorbed on Bare Indium Tin Oxide Electrode Surfaces
- In situ Observation of Electron Transfer Kinetics of Cytochrome c Adsorbed on ITO Electrode with Applying Pulse Potential Step with Slab Optical Waveguide Spectroscopy
- Low Voltage Pulse Application to Biological Cells
- Effect of Low-voltage Pulse on Cell Elimination
- Label-Free and Noninvasive Monitoring of Cell Differentiation on Spheroid Microarray
- Low Voltage Pulse Application to Biological Cells