Studies on Some Modification of Technicon's SMA-12/60 System for Reduction of Sample Volume
スポンサーリンク
概要
- 論文の詳細を見る
As a Technicon's SMA 12/60 (Survey type) Auto Analyzer was introduced to our clinical chemistry laboratory to perform a major role in our routine works, a point was raised particularly from the pediatric department where the amount of serum required (2 ml) was considered to be oo great. In order to solve the problem and improve precision of the re- sults, the following modifications of the SMA 12/60 system have been accomplished.<BR>1. Introduction of predilution system for all channels and ultra violet methods to LDH, GOT and GPT (substituted for glucose channel) using automatic blank correction without a dialyzer, as previously reported by us.<BR>2. Substitution of the bromocresol green method for the HABA method in albumin channel to minimize interference by bilirubin in serum.<BR>3. Removal of a preheating bath from uric acid channel to decrease carry-over contami- nation and addition of a time-delay coil to cholesterol channel to increase the sensitivity of the method.<BR>As a result of the modifications, the sample volume per profile was reduced to 0.4 ml without any sacrifice in speed, accuracy or precision, and the devised system has been successfully performed in our laboratory over 16 months.
- Japan Society of Clinical Chemistryの論文
著者
-
金井 正光
信州大学医学部付属病院中央検査部
-
近藤 ヒロミ
信州大学医学部付属病院中央検査部
-
藤原 正子
信州大学医学部付属病院中央検査部
-
野本 昭三
信州大学医学部付属病院中央検査部
-
古橋 崇子
信州大学医学部付属病院中央検査部
関連論文
- 透析関連事故調査報告
- 尿中に悪性細胞が出現した原発性精嚢腺癌の1症例
- 吸引細胞診で診断できた正中頸嚢胞扁平上皮癌の1症例
- カドミウム汚染地域住民における尿中低分子量蛋白排泄の個人内変動
- 生化学自動分析装置を用いた亜鉛比色測定法
- 肝癌患者にみられる自己抗体について-抗核抗体を中心に-
- 血清亜鉛値による亜鉛欠乏症検出システムの現況 : その欠落部への提言
- 2.ビタミンA結合たん白Retinol-binding proteinの分離, 精製について
- Pyruvate kinase欠乏による溶血性貧血の1例
- 肺塞栓を合併したminor anomaly型多発性骨髄腫の1例
- Clinical significance of fecal chymotrypsin test in chronic pancreatitis. A comparative study of the its value with pancreozymin-secretin test, PFD test, and endoscopic retrograde pancreatography. : A Comparative Study of the Its Value with Pancreozymin-S
- Detection of anticentromere antibodies (ACA) in sera of patients with autoimmune liver diseases
- Study on Immunological determination of Retinol-binding protein in biological fluids
- Determination of Low Levels of GOT Activity by a Diazonium Salt Coupling and Ultraviolet Methods, using "System Olli 3000" Analyzer.
- Radioimmunoassay of Retinol-binding Protein and its use for an Early Detection of Renal Tubular Disorders and Differentiation of Proteinuric Patterns
- Retinol-binding Protein Levels in Blood and Urine from Patients with "Itai-Itai" Disease: Pathological Mechanism for its Increased Excretion
- 自己免疫性肝疾患における抗セントロメア抗体 (ACA) の臨床的意義
- An On-line Data Processing and Control System for a Multi-channel:Automatic Analyzer (SMA12/60).
- Studies on Some Modification of Technicon's SMA-12/60 System for Reduction of Sample Volume
- Dissociation and Dialysis of Serum Protein-bound Thyroxine in a Continuous Flow Dialyzing System
- A Colorimetric Direct Method for the Determination of Serum Copper by Use of TAMSMB
- Application of UV-method to Technicon Auto Analyzer