Impact of Spatial Diversity Reception on SAR Reduction in Implant Body Area Networks
スポンサーリンク
概要
- 論文の詳細を見る
Wireless capsule endoscopy (WCE) is now one of most important applications in implant body area networks (BANs). WCE requires high throughput performance due to its real-time data transmission, whereas the communication performance depends much on the transmit power, which is strictly regulated in order to satisfy a safety guideline in terms of specific absorption rate (SAR). Spatial diversity reception is well known to improve the wireless performance without any temporal and spectral resource expansion. Additionally, applying spatial diversity reception to WCE systems can be expected to not only improve the wireless communication performance but also to reduce SAR. Therefore, this paper investigates the impact of spatial diversity reception on SAR levels for the 400MHz medical implant communication service (MICS) band. To begin with, based on finite-difference time-domain (FDTD) simulations for implant BAN propagation with a numerical human body model, we first calculate the BER performance and derive the required transmit power to secure a permissible BER. Then, this paper calculates the local peak SAR under the required transmit power when the implant transmitter moves through the digestive organs. Finally, our simulation results demonstrate that applying spatial diversity reception can significantly reduce SAR in implant BANs.
著者
-
Wang Jianqing
Nagoya Inst. Of Technol. Nagoya Jpn
-
WANG Jianqing
Nagoya Institute Technology
-
ANZAI Daisuke
Nagoya Institute Technology
-
AOYAMA Sho
Nagoya Institute Technology
-
YAMANAKA Masafumi
Nagoya Institute Technology
-
AOYAMA Sho
Nagoya Institute of Technology
-
ANZAI Daisuke
Nagoya Institute of Technology
関連論文
- Uncertainty of the One-Gram Averaged Spatial Peak SAR in Human Head for Portable Telephones due to Average Procedures
- Localized Specific Absorption Rate in the Human Head in Metal-Framed Spectacles for 1.5 GHz hand-Held Mobile Telephones
- A Practical Approach for Estimation of Load Effect Produced by Ferrite Core Attached to Wire above a Ground Plane (特集 〔平成10年度〕電気関係学会東海支部連合大会)
- B-4-40 Statistical Determination of Exposure Levels in a Multiple-Frequency Whole-Body Exposure System
- Impact of Spatial Diversity Reception on SAR Reduction in Implant Body Area Networks
- Electromagnetic Fields Measurement and Safety Consideration in Magnetic Confinement Fusion Test Facilities
- Performance Evaluation on RSSI-Based Localization for Capsule Endoscopy Systems with 400 MHz MICS Band Signals