Electromagnetic Fields Measurement and Safety Consideration in Magnetic Confinement Fusion Test Facilities
スポンサーリンク
概要
- 論文の詳細を見る
The environmental electromagnetic fields were measured around a magnetic confinement fusion test facility namely Large Helical Device (LHD) which is equipped with large superconducting magnet coils system and high-power plasma heating systems of Neutral Beam Injection, Electron Cyclotron resonance Heating and Ion Cyclotron Range of Frequencies (ICRF) heating. The leakage of the static magnetic field from the LHD was less than 1.2 mT, and it varied according to the coil operation. The extremely low frequency electromagnetic field was measured around power supply units for the coil system, and the magnetic field of higher than the guideline level of the International Commission on Nonionizing Radiation Protection (ICNIRP) was predicted. Leakage of high frequency electromagnetic field from the ICRF was observed in bursts according to plasma shots. The measured values were less than the occupational guideline levels. Although the electromagnetic fields were less than the regulation levels, more monitoring survey is necessary from the view point of occupational safety.
- 社団法人 プラズマ・核融合学会の論文
著者
-
Fujiwara Osamu
Nagoya Institute of Technology
-
Wang Jianqing
Nagoya Institute Of Technology
-
Uda Tatsuhiko
National Institute For Fusion Science
-
Wang Jianqing
Nagoya Inst. Of Technol. Nagoya Jpn
-
Tanaka Masahiro
National Institute For Fusion Science
-
DEJI Shizuhiko
Gifu University of Medical Science
関連論文
- Correlation between mass-averaged SAR and temperature elevation in human head model for RF near-field exposure from 1 to 6 GHz (マイクロ波)
- Correlation between mass-averaged SAR and temperature elevation in human head model for RF near-field exposure from 1 to 6 GHz (環境電磁工学)
- B-4-38 Thresholds Inducing Behavioral Sign of Thermal Stress for 2.45-GHz Microwave Exposure in Rabbits
- Topics in EMC Issues Related to Safety and Secure Social Life
- Effects of 2.45 GHz Electro-Magnetic Field on Mutation in the lacZ-Transgenic Mouse
- Uncertainty of the One-Gram Averaged Spatial Peak SAR in Human Head for Portable Telephones due to Average Procedures
- Localized Specific Absorption Rate in the Human Head in Metal-Framed Spectacles for 1.5 GHz hand-Held Mobile Telephones
- FDTD simulation of temperature elevation in rabbit eye due to microwave energy (環境電磁工学)
- Temperature Elevation in the Eye of Japanese Male and Female Models for Plane Wave Exposures
- Temperature Elevation in Rabbit Eye Irradiated by 2.45-GHz Exposure Systems
- Correlation between Mass-Averaged SAR and Temperature Elevation in Human Head Model for RF Near-Field exposure from 1 to 6GHz
- A Method for Estimating Wideband Transients Using Transmission Loss of High Performance Semi-Rigid Coaxial Cable
- A Formula for Simply Estimating Core Temperature Elevation in Different Species Due to Far-field Exposure
- Formula for estimating whole-body average SAR in human models due to plane-wave exposure at resonance frequency (環境電磁工学)
- B-4-25 Uncertainty of Temperature Elevation in the Eye Due to Microwave Energy
- Discussion on Temperature Increase in Human Body Due to Dipole Antenna in Terms of Green's Function
- FDTD modeling of electromagnetic and thermal dosimetry in human for microwave exposures (マイクロ波)
- Preliminary Experiments on Hydrogen Isotope Separation by Water-Hydrogen Chemical Exchange under Reduced Pressure
- Application of Proton-conducting Ceramics and Polymer Permeable Membranes for Gaseous Tritium Recovery
- Development of Tritium Cleanup System for LHD using Nonvolatile Getter Materials
- Hydrogen Extraction Characteristics of Proton-conducting Ceramics under a Wet Air Atmosphere for a Tritium Stack Monitor
- Effect of Plated Platinum Electrode on Hydrogen Extraction Performance Using CaZrO_3-based Proton-Conducting Ceramic for Tritium Recovery System
- Hydrogen Extraction Using One-end Closed Tube Made of CaZrO_3-based Proton-conducting Ceramic for Tritium Recovery System
- Design of Gaseous Tritium Recovery System Applying Commercially Available Membrane-Type Dehumidifier
- A Practical Approach for Estimation of Load Effect Produced by Ferrite Core Attached to Wire above a Ground Plane (特集 〔平成10年度〕電気関係学会東海支部連合大会)
- Measurement and Verification of Complex Permeability of Ferrite Material by S-Parameter Techniques
- B-4-40 Statistical Determination of Exposure Levels in a Multiple-Frequency Whole-Body Exposure System
- Adsorption Characteristics of Water Vapor on Zeolitic Materials for Honeycomb-Type Adsorbent
- Impact of Spatial Diversity Reception on SAR Reduction in Implant Body Area Networks
- Infinitesimal Concentration Hydrogen Analyzer Using Trace Reduction Detector (TRD)
- Interaction of Microwaves with Synthetic Type A Zeolite Containing Water
- Electromagnetic Fields Measurement and Safety Consideration in Magnetic Confinement Fusion Test Facilities
- Adsorption Behavior of Lithium from Seawater using Manganese Oxide Adsorbent
- Interaction of Microwaves with Synthetic Type A Zeolite Containing Water (Special Issue : Advanced Plasma Science and Its Applications for Nitrides and Nanomaterials)
- Fuel Particle Balance Study in FFHR DEMO Reactor
- Optical Emission and Mass Spectra Observations during Hydrogen Combustion in Atmospheric Pressure Microwave Plasma
- Performance Evaluation on RSSI-Based Localization for Capsule Endoscopy Systems with 400 MHz MICS Band Signals