Electrochemical Preparation and Mechanical Properties of Dog-bone Cu Foils
スポンサーリンク
概要
- 論文の詳細を見る
Dog-bone shaped specimens of Cu foils were fabricated by a combination of electrodeposition and photolithography to investigate the effect of electrochemical condition on mechanical properties of the foils. Electrodeposition of Cu was conducted on a substrate with a dog-bone shaped metallic surface from an acidic CuSO4 solution at a constant current density. Mechanical properties of the Cu foils were investigated by tensile test. From the results of the test, we found that tensile strength was increased but strain to failure was decreased with increasing current density. In addition, SEM observations for the Cu specimens prepared with different current densities revealed that the crystalline size became smaller with increase in current density till it reached a value. We concluded that mechanical properties of the Cu foils are related to the grain size of the Cu deposits.
- 公益社団法人 電気化学会の論文
著者
-
Tada Eiji
Department Of Cardiology New Tokyo Hospital
-
Ohguchi Ken-ichi
Department Of Material Science And Engineering Akita Univ.
-
OHGUCHI Ken-ichi
Department of Materials Science and Engineering, Faculty of Engineering and Resource Science, Akita University
-
MUSHA Gaku
Graduate School of Engineering and Resource Science, Akita University
-
HADEHARA Ken
Sanyo Special Steel Co., Ltd.
-
MIURA Yuta
Graduate School of Engineering and Resource Science, Akita University
関連論文
- PJ-727 Percutaneous Coronary Intervention for Acute Myocardial Infarction in the Elderly : Comparison on Clinical Outcome between Younger Patients, Septuagenarians and Octogenarians(Coronary revascularization, PCI-17, The 71st Annual Scientific Meeting of
- OJ-102 Coronary Artery Perforations : Incidence, Predictors and Clinical Outcomes : Multicenter Registry in Japan(Coronary revascularization, PCI-06, The 71st Annual Scientific Meeting of the Japanese Circulation Society)
- Combined Brachytherapy and External Beam Radiotherapy in Normal Monkey Brains : Experimental Radiation Necrosis Evaluated by Sequential Magnetic Resonance Imaging
- The Effects of Straining Frequency and Stress Ratio on Polarization Current Responded to Cyclic Strain in a Commercial Iron
- Effect of Adjuvant Iridium-192 Brachytherapy on the Survival of Patients with Malignant Gliomas
- Electrodeposition of PbO_2 Thin Films at the Interface of Two Immiscible Liquids
- Elastic-Plastic-Creep Simulation of Pb/Sn Solder Alloys by Separation of Plastic and Creep
- Plasticity-Creep Separation Method for Viscoplastic Deformation of Lead-Free Solders(Advanced Technology of Experimental Mechanics)
- Galvanic Corrosion of a Zn/steel Couple in Aqueous NaCl
- Electrochemical Preparation and Mechanical Properties of Dog-bone Cu Foils
- Electrochemical Oscillation During Electrodeposition of Zinc at the Interface Between Two Immiscible Liquids