<B>Background:</B> The association of gene variants with the recurrence of atrial fibrillation after catheter ablation is still unclear. <B>Methods:</B> A total of 383 consecutive patients of AF were included, and 189 patients underwent catheter ablation for drug-refractory AF. The single nucleotide polymorphisms (SNPs) (rs13376333, rs2200733, and rs7193343) were genotyped using real-time polymerase chain reaction. <B>Results:</B> The rs7193343 variant was the independent associated factor of non-PAF (paroxysmal AF). In the PAF group, the rs7193343 variant was independently associated with AF recurrence after catheter ablation; however, the rs2200733 and rs13376333 variants were not associated with AF recurrence in this group. The combination of the rs7193343 and rs2200733 risk alleles was associated with a better predictive power in PAF patients. In contrast, in the non-PAF group, the SNPs were not associated with recurrence. <B>Conclusions:</B> The rs7193343 variant was associated with AF recurrence after catheter ablation in the PAF patients but not in the non-PAF patients. The rs7193343 variant was the independent associated factor of non-PAF.
著者
-
Chen Shih-ann
Taipei Veterans General Hospital
-
Hu Yu-Feng
Taipei Veterans General Hospital
-
Yeh Hung-I
Mackay Memorial Hospital
関連論文
- Catheter Ablation of Paroxysmal Atrial Fibrillation : Target the Initiator vs Substrate
- Rotational Angiography: Use of Intra-procedural Imaging to Guide AF Ablation
- TGF-β1 Level and the Outcome after Catheter Ablation for Atrial Fibrillation
- Association of Single Nucleotide Polymorphisms with the Recurrence of Atrial Fibrillation after Catheter Ablation
- Lown-Ganong-Levine Syndrome in a Patient with Hyperthyroidism
- Noncontact Mapping Guided Ablation of Atrioventricular Nodal Reentrant Tachycardia in a Patient with Persistent Left Superior Vena Cava
- Effects of Pacing and High-Pass Filter Settings on Ventricular Bipolar Electrograms in Implantable Cardioverter-Defibrillator Systems: Implication for Inappropriate Shocks Due to T Wave Oversensing
- Predictor for Inappropriate Shocks Due to T Wave Oversensing Using the R and T Wave Amplitudes of Ventricular Bipolar Electrograms in Implantable Cardioverter-Defibrillator Systems
- Optimal Assessment of the Atrial Substrate to Guide Persistent AF Ablation
- Disparities of Fibrillatory Electrogram Characteristics in Patients with Persistent and Long-Lasting Atrial Fibrillation
- Differences of Atrial Electrophysiological Properties between Vagal and Sympathetic Type Atrial Fibrillations
- Reversal of Tachycardiomyopathy in a Patient with Incessant Form Ventricular Tachycardia Originating from Left Sinus of Valsalva after Successful Ablation Guided by EnSite NavX System
- New Insight of Chronic Atrial Fibrillation: Lessons from CHADS2 and CHADS-Vas Score and Long-Term Catheter Ablation Outcome
- Atrial Fibrillation : From the Bench to the Operating Theater