Numerical Simulation of Water Temperature in a Spent Fuel Pit during the Shutdown of Its Cooling Systems
スポンサーリンク
概要
- 論文の詳細を見る
In order to evaluate the heat loss and water temperature in a spent fuel pit (SFP) after the shutdown of its cooling systems, three dimensional thermal hydraulic behavior was calculated using the CFD software, FLUENT 6.3.26. In the calculations, the decay heat calculated by using the burn-up calculation software, ORIGEN 2.2, and the previously proposed correlation for evaporation heat fluxes from the water surface to air flow were used. Water temperatures were almost uniform in the SFP, and this indicated that one-regional calculation model might be able to obtain an average water temperature accurately. Comparisons of calculated results with measured temperatures showed that ORIGEN 2.2 gave good prediction of the decay heat for fuel assemblies with large decay heat which had been taken relatively recently from the shutdown reactor core. But ORIGEN 2.2 overestimated for longtime cooled fuel assemblies with small decay heat. The previously proposed evaporation heat flux correlation overestimated the temperature increasing rate of the SFP water.
著者
-
Murase Michio
Institute Of Nuclear Safety System
-
Utanohara Yoichi
Institute Of Nuclear Safety System Inc.
-
YOSHIDA Yoshitaka
Institute of Nuclear Safety System, Inc.
-
Yoshida Yoshitaka
Institute Of Nuclear Safety System Inc.
-
Yanagi Chihiro
Institute Of Nuclear Technology Institute Of Nuclear Safety System Inc.
-
IWAKI Takanori
The Kansai Electric Power Co.
-
NAGAE Takashi
The Kansai Electric Power Co.
関連論文
- Countercurrent Gas-Liquid Flow in a PWR Hot Leg under Reflux Cooling (II) : Numerical Simulation of 1/15-Scale Air-Water Tests
- Countercurrent Gas-Liquid Flow in a PWR Hot Leg under Reflux Cooling (I) : Air-Water Tests for 1/15-Scale Model of a PWR Hot Leg
- Void Fraction in a Four by Four Rod Bundle under a Stagnant Condition
- Analysis of Noncondensable Gas Recirculation Flow in Steam Generator U-Tubes during Reflux Condensation Using RELAP5
- Experimental Study on Transient Boiling Heat Transfer in an Annulus with a Narrow Gap
- ICONE11-36177 EXPERIMENTAL STUDY ON TRANSIENT BOILING HEAT TRANSFER IN AN ANNULUS WITH A NARROW GAP
- Reflux Condensation Heat Transfer of Steam-Air Mixture under Turbulent Flow Conditions in a Vertical Tube
- Evaluation of Reflux Condensation Heat Transfer of Steam-Air Mixtures under Gas-Liquid Countercurrent Flow in a Vertical Tube
- Numerical Simulation of Countercurrent Gas-Liquid Flow in a PWR Hot Leg under Reflux Cooling
- Numerical study on mountain waves generated by a two-dimensional mountain and their effect on the transport of Yellow Sand
- Development and Evaluation of a Fast Calculation Method for Gamma Ray Skyshine Dose Using Data Libraries
- Modeling and Validation of In-Vessel Debris Cooling during LWR Severe Accident
- Effects of Liquid Properties on CCFL in a Scaled-Down Model of a PWR Hot Leg
- Correlation for countercurrent flow limitation in a PWR hot leg
- Development of Fitting Methods Using Geometric Progression Formulae of Gamma-ray Buildup Factors
- Detection of Cavitation States with Microphone Placed Outside Pipe Components
- Influence of Local Flow Field on Flow Accelerated Corrosion Downstream from an Orifice
- Numerical Simulation of Water Temperature in a Spent Fuel Pit during the Shutdown of Its Cooling Systems
- Evaluation of Heat Loss and Water Temperature in a Spent Fuel Pit
- One-Region Model Predicting Water Temperature and Level in a Spent Fuel Pit during Loss of All AC Power Supplies
- Correlation between Flow Accelerated Corrosion and Wall Shear Stress Downstream from an Orifice