The Study on a Secondary Electron Multiplier Tube(III)
スポンサーリンク
概要
- 論文の詳細を見る
A 12-stage Cu-Be electron multiplier tube was constructed and mounted in the high vacuum mass spectrometer at Osaka University. The following improvements for the construction, comparing with the similar tube previously reported, were made: 1)plane electrodes for deflecting the ion beam injecting the conversion dynode of multiplier were located behind the defining slit, 2)The several dynodes near the top of the tube were covered by a permalloy cylinder for shielding stray magnetic field of the magnet. The output current of multiplier was measured by a vibrating reed electrometer. As the results of the preliminary investigation of multiplier characteristics, the shape and height of mass peaks were found to be considerably affected by the voltage supplying on the deflecting electrodes and the proper voltage depended on the ion energy. The stability of multiplier gain(∼6×10<SUP>3</SUP>)was fairly sufficient for measuring isotope ratio. For example, the measured <SUP>20</SUP>Ne/<SUP>22</SUP>Ne ratio was 10. 563±0.006(not corrected for mass discrimination). At the ultimate pressure in the mass spectrometer, the background mass spectra up to m/e∼150 were recorded and some hydrocarbon fragment peaks corresponding to 10<SUP>-16</SUP>-10<SUP>-18</SUP> amps. were found in C<SUB>2</SUB>-C<SUB>7</SUB> region. And mass peaks below 10<SUP>-16</SUP> amps. show very fluctuated top, but such statistical fluctuation could be smoothed out by using the amplifying system with sufficiently time constant and low speed scanning. Under such condition, the ion current down to 1-2×10<SUP>-19</SUP> amps. could be detected the noise level of amplifying system.kn-abstract=
- 日本質量分析学会の論文
著者
関連論文
- 8a-H-11 Hg,Znの原子質量
- 神戸港周辺海域の放射能調査 (第1報)
- 真空分析計(I) : 測定技術, 音響
- 2D4 スミス型磁場による同位元素分離の予備実験 (III)
- 17D1. Ti Evapor Pumpについて
- 大型質量分析器による原子質量測定 : 原子核実験
- 大型質量分析器による二重線質量差測定. II. : 原子核実験
- 954を使用せる微少電流測定装置について
- 7p-D-1 隕石中の宇宙線起源核種について
- 原子質量
- 質量分析の現状
- 質量分析計の真空
- 超高真空質量分析計 (II) : 金属製超高真空装置の問題点および高真空中の残留ガスについて
- 宇宙化学
- 残留ガスの分析 : 油拡散ポンプ-液体窒素トラップ-ステンレス系
- 小型イオン増倍管
- 金属製真空系における残留ガス
- 11a-Q-8 微小イオン電流測定用二次電子増倍管
- 19B-4 オメガトロン(I)
- 一様強磁場発生電磁石の設計及びその性能について
- The Measurement of Vapor Pressure - On the Some Ploblems about Vacuum Technique -
- A Mass Spectrometer Type of Leak Detector using Hydrogen
- Production of Ar38, Kr80, Kr82, and Xe128 Tracers by the Neutron Irradiation in JRR-2
- 太陽系元素の年令
- 130Teの二重ベーター崩壊半減期
- 有機分析用高分解能質量分析計
- 真空分析計
- A Mass Spectrometer for the Micro-analysis in Osaka University(I)
- The Study on a Secondary Electron Multiplier Tube(II)
- The Study on a Secondary Electron Multiplier Tube(III)
- Vacuum Technique
- Image Contractor
- 同位体比測定法における最近の諸問題 (同位体比測定シンポジウム(特集))
- Mass Spectrometer Type Leak Detector
- ASTM-E14(U.S.A.),G.A.M.S.(France),Hydrocarbon research group(G.B.)のJoint meetingに出席して
- Isotope Dilution Method
- 2-C-2 大型質量分析器の建設経過に就て(2C 原子核実験)
- 11C-8 大型質量分析器によるDoublet質量差の測定について(原子核実験)
- 1.IV.4 スミス型分析器による同位元素分離の予備実験(I)(原子核)
- 2-C-1 同位元素分離用質量分析計の製作 : 予備実験(2C 原子核実験)
- タイトル無し
- Vacuum Technique V.