網膜の剥離現象に対するモデル的考察
スポンサーリンク
概要
- 論文の詳細を見る
The retinal traction in rabbits has been measured by Kikkawa et al.. The time elapsed from the onset to the disruption can be obtained. Since the rate of traction is known, the amount of elongation of the chorio-retinal complex up to retinal disruption can be calculated. Qualitatively, the amount of the critical elongation of the chorio-retinal complex up to retinal disruption is larger with a high traction rate than with a low traction rate.<BR>For the above experiments, we have taken the three-element mechanical model. The model is stretched with various traction rates and the relation between the rates and the critical elongation in the model is considered. It is shown that the tendency between the retina and the model is similar.<BR>(J. Jpn. Soc. Biorheol., 2(1), 68~71, 1988).
- 特定非営利活動法人 日本バイオレオロジー学会の論文
著者
関連論文
- 粉体層や生体試料への円すい体の挿入について
- 網膜の剥離現象に対する推察II
- 網膜の剥離現象に対するモデル的考察 : 法線方向と切線方向との比較
- 血管壁形状と血流との関連
- より糸のまげ
- 粉体堆積についての推察
- ある自然現象への接近
- 圧力分布による粉体流出 : 双曲線容器の場合
- 粉体内における圧力の伝達
- 左射状動脈前下行枝におけるアテローム性動脈硬化症についての心筋架橋の血液流動学的考察