オートアナライザーによる油脂及び油脂誘導体中の遊離脂肪酸の自動比色定量法
スポンサーリンク
概要
- 論文の詳細を見る
An automated colorimetric method based on continuous flow analysis has been developed for determining free fatty acids in fats and oils and their derivatives.<BR>A 2-propanol solution of a sample was directly introduced into a Technicon Auto Analyzer. <I>o</I>-Nitrophenylhydrazine (ONPH) solution and <I>N</I>-ethyl-<I>N</I>- [3- (<I>N</I>, <I>N</I> methylamino) propyl] carbodi-imide (EDC) solution containing 5% pyridine were added to the sample solution, followed by heating at 60°C for 12min. The free fatty acids in the sample were converted the corresponding <I>o</I>-nitrophenylhydrazides. The solution was mixed with 1% KOH solution to decrease the absorbance of the reagent blank, followed by measurement at 550nm. The method provides a common molar response to a series of fatty acid from caprylic acid to oleic acid. The sample capacity of themethod is 2040 samples/h. Its reproducibility is within 1% relative and recovery, from of 97100%. It was successfully used for determining lipase activity and quantitating free fatty acids in various fatty acid derivatives.