Methods of determination of sulfur oxides in a large-scale flue was examined. The heating of sampling tube was successfully done by an application of steam-jacket tubes.<BR>Theoretical values agreed well with those obtained either by JIS neutralization method, by barium chloranilate method, by Arsenazo-III method, or by sulfur dioxide detector tube method. Sulfur trioixde in the flue gases was simultaneously determined and was found to be less than 3%, the remaining 97% or more being sulfur dioxide. Since, therefore, the amount of sulfur dioxide may represents the concentration of sulfur oxides in the flue gases, the use of the sulfur dioxide detector tube is a convenient method for the measurement of the whole concentration of sulfur oxides in the waste flue gases.