真空融解法における炉中ガス吸収の動的機構(ノート)
スポンサーリンク
概要
- 論文の詳細を見る
A dynamic behavior of both extracted gas and metal vapor evolved from fused steel sample (NBS#1041) in the vacuum fusion analysis was studied. Metal vapor was trapped on a moving surface of an alkalineless glass tape which passes by a 10 mm wide window at a speed of 2 mm per sec. Iron and manganese deposited on the surface of the tape were extracted in an ethanolamine-NaOH solution and determined by a polarographic method.<BR>A variation in the pressure change of the extracted gas was recorded with a Pirani gauge at an outlet of the extraction pump. And these results were compared with the analytical values of oxygen obtained by an ordinary method [See Bunseki Kagaku, 14, 540 (1965) ].<BR>The difference in the extent of gas absorption in the successive analyses was closely related to the degree of the overlap with the metal vapor which at first evolved within 4 to 20 sec after the addition of a sample in a crucible.<BR>The gas absorption in a vacuum fusion analysis was proved to be reduced by such a method using a metal bath or graphite capsules, which prevent the overlap of the evolution of gas and metal vapor.
- 社団法人 日本分析化学会の論文
著者
関連論文
- 2-(2-チアゾリルアゾ)-5-ジメチルアミノフェノールを用いる溶媒抽出によるバナジウムの吸光光度定量
- 金属中ガス分析法の進歩(III) : 同位体希釈法
- 14MeV中性子放射化分析法による帯域溶融純鉄中の酸素の定量
- 銀,パラジウムおよびこれらの合金中の酸素の定量
- 高分子量アミン-ベンゼン溶液抽出法による高合金鋼中のタンタルの定量
- 真空融解法によるフェロボロン中の酸素の定量
- 同位体希釈法による鉄鋼中の窒素の定量
- 真空融解法における炉中ガス吸収の動的機構(ノート)
- 不しゅう鋼中の酸素の定量
- 同位体希釈法による金属中の酸素の定量
- 金属中ガス分析法の進歩-6-発光分光分析
- マンガンよおびクロムの真空融解炉中におけるガス吸収について