ガスクロマトグラフ法による亜硝酸の定量
スポンサーリンク
概要
- 論文の詳細を見る
ο-Phenylenediamine reacts with nitrite to form 1<I>H</I>-benzotriazole which can be extracted into MIBK.By means of injection of this MIBK layer into gas-chromatograph equipped with a thermal conductivity detector, the nitrite is determined from the peak height. Though the sensitivity is low compared with the colorimetric method, the gas-chromatographic method is superior in the specificity.<BR>Put 20 m<I>l</I> of the sample solution and 3 m<I>l</I> of 1 <I>N</I> hydrochloric acid into a 100-m<I>l</I> separatory funnel, and then, add 2 m<I>l</I> of 0.0187 <I>M</I> ο-phenylenediamine solution. After standing for 20 min, 5 m<I>l</I> of 1 <I>M</I> sodium acetate is added and 11 g of sodium chloride is added. Then, the 1<I>H</I>-benzotriazole formed is extracted into 1 m<I>l</I> of MIBK by shaking for 10 min andthe MIBK extract is dried with 0.5 g of molecular sieves 3 A. Five micro liters of the MIBK extract isinjected into the gas-chromatograph and the peak height is measured. The nitrite content is calculated by using a calibration curve which has been drawnpreviously by experiments with known amounts of nitrite.