次亜リン酸を支持電解質とするチタン(IV)のポーラログラフィー(ノート)
スポンサーリンク
概要
- 論文の詳細を見る
Polarographic behavior of titanium in hypophosphorus acid supporting electrolyte has been studied in the view of determination of titanium. Titanium gave a well-defined diffusion-controlled wave in this medium. The log(<I>i/i<SUB>d</SUB>-i) vs.</I> voltage diagram was linear, and its slope corresponded closely to a reversible one electron reduction. The half-wave potential was-0.27 V <I>vs.</I> S. C. E. and <I>i<SUB>d</SUB>/C·m<SUP>2/3</SUP> ·t</I><SUP>1/6</SUP> was 1.43 at 25°C in 1.2<I>M</I> hypophosphorus acid. A linear relationship was obtained between the diffusion current and the concentration over the range of 2.2 ×10<SUP>-3</SUP>3.7 × 10<SUP>-4</SUP><I>M</I>. The precision of the calibration curve for titanium as the standard deviation was 1.77% for concentration of 0.75 × 10<SUP>-3</SUP><I>M</I> and 3.79% for 0.75 × 10<SUP>-4</SUP><I>M</I>. Antimony (III) and molybdenum (VI) gave cathodic waves and interfered with the titanium determination. The interference from iron and copper was easily eliminated by boiling the solution with hydrochloric acid and potassium thiocyanate. Hypophosphorus acid as supporting electrolyte was thus especially useful for determination of titanium in the presence of large quantities of iron and copper.
- 社団法人 日本分析化学会の論文
著者
関連論文
- 塩化物抽出分離-直流ポーラログラフ法によるヒ素の定量
- ポーラログラフ法による鉄鋼,鉄鉱石中のマンガンの定量
- マンガン(III)トリエタノールアミン錯体に対するシアンイオンの影響
- 溶媒抽出-直流ポーラログラフ法によるヒ酸の間接定量
- 溶媒抽出-直流ポーラログラフ法によるケイ酸の間接定量
- 溶媒抽出-直流ポーラログラフ法によるリン酸の間接定量
- ポーラログラフによる鉄鉱石,鉄鋼中のヒ素の定量
- 次亜リン酸を支持電解質とするチタン(IV)のポーラログラフィー(ノート)
- ポーラログラフ法によるバナジウムとモリブデンの定量