Mass Transfer in Cryogenic Distillation Column Separating Hydrogen Isotopes.
スポンサーリンク
概要
- 論文の詳細を見る
A simulation model was proposed to study the mass and heat transfer rates in hydrogen isotope distillation columns. The model is on the basis of the analogy : the mass transfer coefficients and effective surface area within the column were estimated by Kosuge's and Onda's correlation in the model. The calculated results by the present model agreed approximately with the experimental observations. The model had a tendency to give slightly higher separation performance. This tendency is due to that the estimated effective surface area might be larger than actual values. The calculated results by the proposed model were compared with those by the stage model also to discuss relationship between the mass transfer rate and the HETP value. The estimated mass transfer rates were almost the same for H-D and D-T systems. This calculated results give a reason why the HETP values were not varied for the difference in physical properties of hydrogen isotopes. The proposed model does not have the parameter that fit the calculated results to the experimental observations. Comparing the calculated results by the proposed model with those by the stage model, we can estimate the HETP value.
- 一般社団法人 日本原子力学会の論文
著者
-
Okuno Kenji
Tritium Engineering Laboratory Japan Atomic Energy Research Institute
-
Yamanishi Toshihiko
Tritium Engineering Laboratory Japan Atomic Energy Research Institute
関連論文
- Simulation of Tritium Behavior after Intended Tritium Release in Ventilated Room
- A Steady-state Simulation Model of Gas Separation System by Hollow-filament Type Membrane Module
- Influence of Framework Silica-to-Alumina Ratio on the Tritiated Water Adsorption and Desorption Characteristics of NaX and NaY Zeolites
- Design Study of Feasible Water Detritiation Systems for Fusion Reactor of ITER Scale
- Durability of Irradiated Polymers in Solid-Polymer-Electrolyte Water Electrolyzer
- Control Characteristics of Cryogenic Distillation Column with a Feedback Stream for Fusion Reactor
- Application of Pressure Swing Adsorption to Water Detritiation Process
- Numerical Estimation Method of the Hydrogen Isotope Inventory in the Hydrogen Isotope Separation System for Fusion Reactor
- ANALYSIS OF CHARACTERISTICS OF CRYOGENIC DISTILLATION COLUMN IN SEPARATION OF HYDROGEN ISOTOPES
- Room-Temperature Reactor Packed with Hydrophobic Catalysts for the Oxidation of Hydrogen Isotopes Released in a Nuclear Facility
- Experimental Study for Characteristics of Cryogenic Distillation Column Having Feedback Stream with H-D-T System.