Demonstration of 10 keV-width K-edge Imaging Using an Energy-Discrimination X-ray Computed Tomography System Utilizing a Silicon-PIN Detector
スポンサーリンク
概要
- 論文の詳細を見る
A high-energy-resolution X-ray Computed Tomography(CT)system is of a first-generation type and consists of an X-ray generator, a turntable, a translation stage, a two-stage controller, a silicon-PIN detector system with amplifiers, a multichannel analyzer(MCA), a counter card(CC), and a personal computer(PC). CT is accomplished by repeating the translation and the rotation of an object, and projection curves of the object are obtained by the linear scanning by moving the object. Both photon-energy level and energy width are determined by the MCA, and the pulses of the discriminated event signal from the MCA are counted by CC in conjunction with PC. The maximum count rate was approximately 5 kcps, and energy-discrimination CT was carried out with a photon-energy resolution of 0.15 keV. To perform iodine K-edge CT, X-ray photons with an energy range from 33.2 to 43.2 keV were used. Next, to carry out cerium K-edge CT, an energy range from 40.3 to 50.3 keV was selected. Using K-edge CT, iodine and cerium molecules were observed at high contrast. Therefore, molecular-level imaging for cancer diagnosis might be accomplished.
著者
-
SATO Eiichi
Department of Physics, Iwate Medical University
-
Sato Eiichi
Department Of Information And Electronics Engineering Niigata Institute Of Technology
-
Watanabe Manabu
The 3rd Department of Surgery, Toho University School of Medicine, 2-17-6 Ohashi, Meguro, Tokyo 153-8515, Japan
-
OSAWA Akihiro
The 3rd Department of Surgery, Toho University School of Medicine
-
HAGIWARA Osahiko
The 3rd Department of Surgery, Toho University School of Medicine
-
MATSUKIYO Hiroshi
The 3rd Department of Surgery, Toho University School of Medicine
-
NANAO Jiro
The 3rd Department of Surgery, Toho University School of Medicine
-
Sato Eiichi
Department of Anatomic Pathology, Tokyo Medical University
関連論文
- X-ray Spectra from Weakly Ionized Linear Copper Plasma
- Enhanced K-edge Angiography Utilizing Tantalum Plasma X-ray Generator in Conjunction with Gadolinium-Based Contrast Media
- Variations in Cerium X-ray Spectra and Enhanced K-Edge Angiography
- Demonstration of 10 keV-width K-edge Imaging Using an Energy-Discrimination X-ray Computed Tomography System Utilizing a Silicon-PIN Detector
- Measurement of Cerium X-ray Spectra Using a Cerium Oxide Powder Filter and Enhanced K-edge Angiography
- X-ray Spectra from a Characteristic X-ray Generator with a Molybdenum Tube
- Quasi-Monochromatic X-Ray Generator Utilizing Graphite Cathode Diode with Transmission-Type Molybdenum Target
- Quasi-Monochromatic Flash X-Ray Generator Utilizing Disk-Cathode Molybdenum Tube
- Intense Characteristic X-ray Irradiation from Weakly Ionized Linear Plasma and Applications
- X-ray Enhancement by Fuorescent Emission using the Plasma X-ray Source
- Water-Window X-ray Source Driven by an Ignitron Pulser
- Epstein-Barr virus-associated enteritis with multiple ulcers after stem cell transplantation : First histologically confirmed case
- Glycopathological Study of Eyelid Tumors and Pseudotumors
- P564 An additional intracoronary thromholysis on reperfusion with PTCA assessed by myocardial perfusion imaging in patients with acute myocardial infarction.
- 0455 Sequential Imagine of Iodine-123 betamethyl pentadecanoic acid(BMIPP)in patients with acute coronary syndrome treated by reperfusion therapy.
- Semi-Monochromatic Plasma Flash Radiography and Its Application to Biomedical Imaging Simulation
- Fundamental Study on a Long-Duration Flash X-Ray Generator with a Surface-Discharge Triode
- 8 The evaluation of micro-coronary vessels using a plasma X-ray angiographic system for better management and cost/effectiveness to ischemic heart disease(Plenary Session 6 (PL6) (I) : Role of Diagnostic Imaging in the Management of Coronary Artery Diseas
- MUC1 mucin expression in follicular dendritic cells and lymphoepithelial lesions of gastric mucosa-associated lymphoid tissue lymphoma
- Expression of Sulfomucins in Normal Mucosae, Colorectal Adenocarcinomas, and Metastases
- Quasi-monochromatic parallel radiography achieved with a plane-focus x-ray tube
- New x-ray irradiation from weakly ionized linear plasma
- High-intensity Quasi-monochromatic X-ray Irradiation from the Linear Molybdenum Plasma
- Mobile submuscular mass resembling a hard-boiled egg : case report
- Use of Scanning Laser Ophthalmoscope Microperimetry in Clinically Significant Macular Edema in Type 2 Diabetes Mellitus
- Branch Retinal Vein Occlusion in a Japanese Patient with Neurofibromatosis 1
- Relation Between Plasma Nitric Oxide Levels and Diabetic Retinopathy
- Treatment of Tibial Pilon Fractures
- Expression of MUC2 Gene Product in Mucinous Carcinoma of the Breast: Comparison with Invasive Ductal Carcinoma
- Magnification Embossed Radiography Utilizing Image-Shifting Subtraction Program
- Energy-Discriminating Gadolinium K-Edge X-ray Computed Tomography System
- Grain Boundary Character and Superplasticity of Fine-Grained Ultra-High Carbon Steel
- X-ray Spectra from Weakly Ionized Linear Copper Plasma
- Performance Evaluation of Trellis-Coded 16 and 32-APSK Schemes (Special Section on Multi-dimensional Mobile Information Networks)
- Monte Carlo Distance Spectrum Method for Estimating BER of Turbo Codes(Coding Theory)
- Indirect imaging of branch retinal vein occlusion using a scanning laser ophthalmoscope
- Poor Prognosis in Elderly Patients Receiving Nonoperative Treatment for Hip Fracture: A Study of 224 Cases at Kofu National Hospital
- A criterion for uniruledness in positive characteristic
- Magnification K-Edge Angiography Utilizing 100-μm-Focus Tungsten Tube and Gadolinium-Based Contrast Media
- Enhanced Magnification Angiography Using 20-μm-Focus Tungsten Tube
- Characteristic X-ray Generator Utilizing Angle Dependence of Bremsstrahlung X-ray Distribution
- Investigation of Energy-Dispersive X-ray Computed Tomography System with CdTe Scan Detector and Comparing-Differentiator and Its Application to Gadolinium K-Edge Imaging
- Projective manifold with the ample vector bundle $^2_\Lambda \mathrm{T_X}$
- Variations in Cerium X-ray Spectra and Enhanced K-Edge Angiography
- Effects of topical carteolol on retinal arterial blood flow in primary open-angle glaucoma patients
- Enhanced K-edge Angiography Utilizing Tantalum Plasma X-ray Generator in Conjunction with Gadolinium-Based Contrast Media
- Quasi-Monochromatic X-Ray Generator Utilizing Graphite Cathode Diode with Transmission-Type Molybdenum Target
- Quasi-Monochromatic Flash X-Ray Generator Utilizing Disk-Cathode Molybdenum Tube
- Uniform vector bundles on a projective space
- X-ray Photon Counting Using 100 MHz Ready-Made Silicon P--Intrinsic--N X-ray Diode and Its Application to Energy-Dispersive Computed Tomography
- Low-Dose-Rate Computed Tomography System Utilizing 25 mm/s-Scan Silicon X-ray Diode and Its Application to Iodine K-Edge Imaging Using Filtered Bremsstrahlung Photons
- Immunohistochemical Analysis of Salivary Gland Tumors: Application for Surgical Pathology Practice
- X-ray Photon Counting Using 100 MHz Ready-Made Silicon P--Intrinsic--N X-ray Diode and Its Application to Energy-Dispersive Computed Tomography