Purpose: The aim of our study was to evaluate the image quality of multiplanar reconstruction images (MPRs) focusing on the effect of z-increment of original axial images using signal to noise ratio (SNR) measurement in in- plane and longitudinal directions.METHODS AND MATERIALS:SNRs of MPRs were calculated using modulation transfer function (MTF) and noise power spectrum (NPS). We scanned a bead phantom with a diameter of 0.1 mm and a water phantom with a diameter of 250 mm for calculating MTF and NPS using a MDCT with 0.5 s per rotation, 1.0 pitch and 64 × 0.6 mm collimation, and 50 mm field of view. Axial images for generating MPRs were reconstructed with standard kernel (B40), and 1.00 mm slice width. Coronal images were generated from two datasets with 0.1 mm and 0.5 mm z-increments of axial images respectively. For measuring the SNRs, the MTFs and NPSs in in-plane and longitudinal directions of each dataset were calculated from coronal bead images and coronal uniform noise images, respectively. Differences of MTF, NPS, and SNR were compared in in-plane and longitudinal directions.RESULTS:The MTF of longitudinal direction of the dataset with 0.1 mm z-increment was higher than the dataset with 0.5 mm z-increment. 10% MTFs of longitudinal direction with 0.1 mm and 0.5 mm z-increments were 0.75 cycles/mm and 0.68 cycles/mm, respectively. Conversely, the NPS of longitudinal direction of the dataset with a 0.1 mm z-increment was lower than the dataset with a 0.5 mm z-increment. As a consequence, the SNRs of longitudinal direction had relatively no difference between the datasets. In in-plane direction, MTFs, NPSs and SNRs had no differences between the datasets.CONCLUSION:A tradeoff relationship was indicated between spatial resolution and noise characteristic in the longitudinal direction due to the effects of different z-increment of original axial images used in generating MPRs. MPR using 0.5 mm z-increment of axial images had comparable SNR to MPR using 0.1 mm z-increment of axial images in our experimental condition.CLINICAL RELEVANCE/APPLICATION:Using 0.5 mm z-increment of original axial images for generating MPRs is effective for reducing the data volume, reconstruction time and transfer time without reducing image quality.
著者
関連論文
- RSNA(北米放射線学会)2009参加報告書
- アモルファスセレンを用いた直接変換型FPD装置における残像現象の測定
- 69 CTのMPR画像解像特性評価法の考察(CT検査画像特性と評価2, 第35回日本放射線技術学会秋季学術大会プログラム)
- 65 CTのMTF算出における2次元フーリエ変換法の応用(CT検査画像特性と評価1, 第35回日本放射線技術学会秋季学術大会プログラム)
- (1)RSNA2009参加報告(国際会議報告)
- 品質管理用Film GAFCHROMIC○R RTQA2を用いた線量検証(第38回秋季学術大会放射線防護・管理関連演題発表後抄録)
- RSNA(北米放射線学会)2009参加報告書
- 覚悟のススメ
- Participating Report of English Presentation Support Seminar