A differential pressure transmitter with an orifice is widely used as a major field flowmeter. A major drawback of this flowmeter at operation site is blockage of an impulse line, which connects a differential pressure transmitter with an orifice tap. By conducting experiments at a water line, we have developed a method to diagnose the blockage of the impulse line based on the evaluation of pressure fluctuations; this is installed on a multi-sensing differential pressure transmitter. This paper utilizes this method to diagnose the blockage at an oil line that carries a highly viscous fluid. In particular, we focus on the relation between the amplitude of the pressure fluctuations at the oil line and the kinetic viscosity (1.0 × 10<SUP>-5</SUP> to 3.0 × 10<SUP>-5</SUP> m<SUP>2</SUP>/s). Through experimental investigations, the following results are derived: (1) The highly viscous fluid in the impulse line does not attenuate the pressure fluctuations transmitting to the multi-sensing differential pressure transmitter. (2) Highly viscous flow in the main line has small pressure fluctuations; however, these fluctuations have the same characteristics of the impulse line blockage as those at a water line. Therefore, the proposed method can diagnose the impulse line blockage at an oil line as well as at a water line.
- 一般社団法人 日本機械学会の論文
著者
-
Uehara Akira
Research Institute For Science And Engineering Waseda University
-
Eino Jyun-ichi
Research Institute For Science And Engineering Waseda University
-
Hashizume Takumi
Research Institute For Science And Engineering Waseda University
-
WAKUI Tetsuya
Osaka Prefecture University
-
MIYAJI Nobuo
Yokogawa Electric Corporation
-
YUUKI Yoshitaka
Yokogawa Electric Corporation
-
HASHIZUME Takumi
Research Institute for Science & Engineering, Waseda University
-
EINO Jyun-ichi
Research Institute for Science & Engineering, Waseda University
関連論文
- C203 DIAGNOSIS OF THICKNESS IN PIPES AND HEAT EXCHANGER TUBES : A CASE OF STRAIGHT PIPES IN WATER LINE(Erosion)
- Model-Based Performance Monitoring with Dynamic Compensation for Heat Utilization Process in Distributed Energy System
- Diagnostics of Impulse Line Blockage with Multi-Sensing Differential Pressure Transmitter at Oil Line
- Diagnostics of Impulse Line Blockage with Multi-sensing Differential Pressure Transmitter at Air Line