Correlation of Abnormal Response of Left Ventricular Ejection Fraction after Exercise and Left Ventricular Cavity-to-Myocardium Count Ratio of Technetium-99m-Tetrofosmin Single Photon Emission Computed Tomography in Patients with Coronary Artery Disease.
スポンサーリンク
概要
- 論文の詳細を見る
The aim of this study was to assess the value of the left ventricular cavity-to-myocardium count ratio (C / M ratio) of technetium-99m (Tc-99m) tetrofosmin single photon emission computed tomography (SPECT) to identify abnormal left ventricular ejection fraction (LVEF) responses after exercise in patients with coronary artery diseases (CAD). We studied 50 patients with recent CAD undergoing rest and exercise first-pass ventriculography to calculate LVEF and rest and exercise Tc-99m tetrofosmin myocardial perfusion SPECT to calculate left ventricular C / M ratios. Group A, consisting of 25 CAD patients with normal responses (increased LVEF ≥ 5% after exercise), had significantly higher rest and exercise C / M ratios than those of the group B, consisting of 25 CAD patients with abnormal responses (increased LVEF <5% after exercise) after exercise. However, the C / M ratios between exercise and rest did not differ significantly between groups A and B. In addition, there was significant correlation between LVEF and C / M ratios in all of the patients. C / M ratios of Tc-99m tetrofosmin myocardial perfusion SPECT are useful parameters for identifying patients with abnormal LVEF responses among patients with CAD.
- International Heart Journal刊行会の論文
著者
-
Kao Albert
Department Of Medical Research China Medical University Hospital
-
Kao Albert
Departments of Nuclear Medicine and Medial Research, China Medical College Hospital
-
Lin Ching-C
Cardiovascular Division, Department of Internal Medicine
-
Ding Hueisch-J
School of Technology for Medical Science and Department of Medical Research, Kaohsiung Medical University
-
Wang Jhi-J
Department of Medical Research, Chi-Mei Medical Center
-
Ho Shung-T
School of Medicine, National Defense Medical Center
関連論文
- Usefulness of technetium-99m hexamethylpropylene amine oxime lung scan to detect inhalation lung injury of patients with pulmonary symptoms/signs but negative chest radiograph and pulmonary function test findings after a fire accident-a preliminary report
- The influence of volatile anesthetics on alveolar epithelial permeability measured by noninvasive radionuclide lung scan
- Technetium-99m Tetrofosmin Myocardial Perfusion Single Photon Emission Computed Tomography in Syndrome X. A Preliminary Report.:A Preliminary Report
- Correlation of Abnormal Response of Left Ventricular Ejection Fraction after Exercise and Left Ventricular Cavity-to-Myocardium Count Ratio of Technetium-99m-Tetrofosmin Single Photon Emission Computed Tomography in Patients with Coronary Artery Disease.