Technetium-99m Tetrofosmin Myocardial Perfusion Single Photon Emission Computed Tomography in Syndrome X. A Preliminary Report.:A Preliminary Report
スポンサーリンク
概要
- 論文の詳細を見る
Syndrome X is used to describe patients with chest pain and a normal coronary angiogram. We reviewed technetium-99m tetrofosmin (Tc-99m TF) myocardial perfusion single photon emission computed tomography (SPECT) results and clinical data of 43 syndrome X patients and 30 healthy controls with normal left ventricular ejection fraction and no cardiac abnormalities. The Tc-99m TF myocardial perfusion SPECT results showed 12 (27.9%) syndrome X patients had normal myocardial perfusion and 31 (72.1%) had abnormal myocardial perfusion, including 6 (14.0%) patients with fixed defects, 20 (46.5%) patients with transient defects, and 5 (11.6%) patients with reverse defects. The results of exercise ECG were not related to perfusion defects in Tc-99m TF myocardial perfusion SPECT. In contrast, all of the 30 (100.0%) healthy controls had normal myocardial perfusion SPECT results. We conclude that abnormal Tc-99m TF myocardial perfusion SPECT is common in syndrome X and does not correlate well with the exercise ECG. However, further studies with larger case numbers and long term follow up in patients with myocardial events are necessary to support our findings.
- International Heart Journal刊行会の論文
著者
-
Shiau Yu-chien
Department Of Nuclear Medicine Far Eastern Memorial Hospital
-
Kao Albert
Department Of Medical Research China Medical University Hospital
-
Lin Cheng
Family Medicine, Chaina Medical College Hospital
-
Kao Albert
Department of Nuclear Medicine and Medieal Reserch, Chaina Medical College Hospital
-
Hsu Hsiu-Bao
Division of Cardiology, Chaina Medical College Hospital
-
Lee Cheng
Medical Research, China Medical College Hospital
関連論文
- Comparison of gallium-67 citrate and technetium-99m tetrofosmin scan to detect Hodgkin's disease
- Usefulness of technetium-99m hexamethylpropylene amine oxime lung scan to detect inhalation lung injury of patients with pulmonary symptoms/signs but negative chest radiograph and pulmonary function test findings after a fire accident-a preliminary report
- The influence of volatile anesthetics on alveolar epithelial permeability measured by noninvasive radionuclide lung scan
- Single Photon Emission Computed Tomography of Technetium-99m Tefrofosmin Myocardial Perfusion Imaging in Patients with Systemic Lupus Erythematosus-A Preliminary Report.
- Technetium-99m Tetrofosmin Myocardial Perfusion Single Photon Emission Computed Tomography in Syndrome X. A Preliminary Report.:A Preliminary Report
- Correlation of Abnormal Response of Left Ventricular Ejection Fraction after Exercise and Left Ventricular Cavity-to-Myocardium Count Ratio of Technetium-99m-Tetrofosmin Single Photon Emission Computed Tomography in Patients with Coronary Artery Disease.