Preparation and Properties of Immobilized Mercuric Reductase in Porous Glass Carriers
スポンサーリンク
概要
- 論文の詳細を見る
The immobilized mercuric reductase covalently coupled to porous glass was prepared and its properties were investigated. Mercuric reductase immobilized on arylamino and carboxyl derivatives exhibited high relative activities about 20-30% compared with soluble enzymes. The optimum pH of mercuric reductase immobilized on these derivatives was 7.5, slightly higher than that of soluble state (7.0-7.2). The stability of mercuric reductase increased with immobilization onto arylamino derivative and the immobilized enzyme maintained at 30℃ for 29 days showed 80-90% of initial activity. As the application of immobilized enzyme, mercuric ion sensor was prepared and it was found that mercuric ion higher than 0.5μM was detectable with this sensor.
- 社団法人 日本セラミックス協会(The Ceramic Society of Japan)の論文
著者
-
Tamiya E
Graduate School Of Engineering Osaka Univ. 2-1 Yamadaoka Suita Osaka 565-0871 Jpn
-
Karube I
Tokyo Univ. Technol. Hachioji‐shi Jpn
-
Karube Isao
Research Center For Advanced Science And Technology The University Of Tokyo
-
Tamiya Eiichi
Japan Advanced Institute For Science And Technology Hokuriku
-
Karube I
Research Center For Advanced Science And Technology University Of Tokyo:research Laboratory Of Resou
-
Suzuki Masayasu
Faculty Of Computer Science And Systems Engineering Kyushu Institute Of Technology
-
Suzuki M
Kyushu Inst. Technol. Fukuoka Jpn
関連論文
- Microfluidic Amperometric Biochips Based on Carbon Nanotube Arrayed Electrodes
- DNA Aptamer-Based Biosensing of Immunoglobulin E Using Carbon Nanotube Field-Effect Transistors
- High-Sensitive and Label-Free Detection of Biomolecules Using Single-Walled Carbon Nanotube Modified Microelectrodes
- 1B16-5 Label-free electrochemical biosensor based on carbon nanotubes
- Direct Ultrasensitive DNA Sensors Based on Carbon Nanotube Field-Effect Transistors
- Ultrasensitive Detection of DNA Hybridization Using Carbon Nanotube Field-Effect Transistors
- 簡易化学発光検出器を用いるヒポキサンチンのフロ-インジェクション分析〔英文〕 (バイオエレクトロケミストリ-の新展開)
- Enhancing the Selectivity of Molecularly Imprinted Polymers
- DNA Condensation Monitoring after Interaction with Hoechst 33258 by Atomic Force Microscopy and Fluorescence Spectroscopy
- Regeneration of NADPH by Cactus Chloroplasts : Coupling Reaction with P450 Monooxygenase
- A Picoliter Chamber Array for Cell-Free Protein Synthesis
- Characterization of a New Keratin-Degrading Bacterium Isolated from Deer Fur
- 微小電極アレイ型DNAチップを用いた遺伝子の電気化学検出
- Purification and Characterization of Cold-Active _L-Glutamate Dehydrogenase Independent of NAD(P) and Oxygen
- Micro Creatinine Sensor Based on ISFET
- Development of a Localized Electroporation System for Transgenic Medaka
- Characterization of L-glutamate:Acceptor Oxidoreductase from Cold-adapted Bacterium
- メディエ-タと共役した銅(2)イオンを有するガラクト-スオキシダ-ゼの電気化学的特性〔英文〕 (バイオエレクトロケミストリ-の新展開)
- Extracellular Lipopolysaccharide Production by Erwinia carotovora
- Atomic Force Microscope-Based Dissection of Human Metaphase Chromosomes and High Resolutional Imaging by Carbon Nanotube Tip
- Enzyme-Linked Sensitive Fluorometric Imaging of Glutamate Release from Cerebral Neurons of Chick Embryos
- Design of Peptide that Recognizes Double-Stranded DNA
- Self-Assembled DNA-Conjugated Polymer for Novel DNA Chip
- Application of a Microchamber Array for DNA Amplification Using a Novel Dispensing Method
- PCR-Based Ribosomal DNA Detection Technique for Microalga (Heterosigma carterae) Causing Red Tide and Its Application to a Biosensor Using Labeled Probe
- A polymerase chain reaction-based ribosomal DNA detection technique using a surface plasmon resonance detector for a red tide causing microalga, Alexandrium affine
- Microbial degradation of nonylphenol in some aquatic environments
- Scanning Near-Field Optical/Atomic Force Microscopy for Fluorescence Imaging and Spectroscopy of Biomaterials in Air and Liquid : Observation of Recombinant Escherichia coli with Gene Coding to Green Fluorescent Protein
- 発光検知型微生物センサによる毒素の測定〔英文〕 (バイオエレクトロケミストリ-の新展開)
- Preparation and Properties of Immobilized Mercuric Reductase in Porous Glass Carriers
- Immobilization of Yeast Cells in Porous Silica Carrier with Sol-Gel Process
- Phase Separation of Halogen-Containing Sodium Borosilicate Glasses
- 粘菌センサを用いる澱粉及びポリビニルアルコ-ルの測定〔英文〕 (バイオエレクトロケミストリ-の新展開)
- Preparation of Enzyme Electrode Based on Self-assembly of Redox Active Polymer and Polyion Complex Formation
- A Thin-Film Glucose Biosensor Based on Hexamethyldisiloxane Plasma-Polymerized Film : Influence of Its Film Thickness on the Platinum Electrode(Nano-interface Controlled Electronic Devices)(Recent Progress of Organic Molecular Electronics
- メディエーターを用いる集積型酵素電池
- Crystal and Molecular Structure of 5, 5′-Bis〔(2, 2, 5, 5-tetramethyl-1-aza-2, 5-disila-l-cyclopentyl)methy1〕-2, 2′-bithiophene
- Development of an Enzyme Sensor Using Multi-enzyme System Immobilized in β-Chitin Membrane
- A Practical Liquid Plug Flow-through Polymerase Chain-Reaction System Based on a Heat-Resistant Resin Chip
- Sensor Chip Using a Plasma-polymerized Film for Surface Plasmon Resonance Biosensors : Reliable Analysis of Binding Kinetics
- Study of DNA Amplification Efficiency Based on Temperature Analyses of the Moving Fluid in a Liquid-Plug Flow PCR System