河川水の熱収支観測法*
スポンサーリンク
概要
- 論文の詳細を見る
In this paper, we described the method of measuring heat balance components of river water and showed time variations in heat balance at Wakamatsu bridge in the middle reach of the Tokoro River in Hokkaido during August 10-16, 1982, as an example. The conductive heat flux through the river bed was measured by a heat flow plate buried at a specific depth as well as thermocouples set in some soil layers between the bed and the heat flow plate. Good agreement was shown between this measured bed conduction and the values calculated using Pivovarov’s method. The reflectivity one water surface and the atmospheric radiation, which were measured using one net-radiometer, two pyranometers and one thermocouple, were discussed as compared with some empirical formulas.
- 北見工業大学の論文
著者
-
中尾 隆志
北見工業大学工学部
-
SADO Kimiteru
Department of Civil Engineering, Kitami Institute of Technology
-
佐渡 公明
Department Of Civil Engineering Kitami Institute Of Technology