標準太陽電池の屋外校正
スポンサーリンク
概要
- 論文の詳細を見る
A description is given of outdoor calibrations of reference solar cells carried out at Kisarazu National College of Technology and a result of the comparison with indoor calibrations at Japan Machinery and Metals Inspection Institute. About three hundred sets of measurements have been performed from March 9 to may 18, 1998. Calibrated cells consist of crystalline Si, polycrystalline Si, amorphous Si, CdS-CdTe and GaAs cells. The cells placed on a plane surface tilted 37 degrees to the horizontal enabled the calibration using a pyrheliometer as it is originally defined by IEC, along with two other methods of calibration ; one utilizing a standard lamp of spectral irradiance (an application of the Japanese method of indoor calibration to outdoor calibration) and the other utilizing the same standard lamp and also an illuminometer (a modified version of the former method). The results obtained in this report are as follows : (1) each method of calibration gave quite accurate efficiencies of the cells, (2) the comparison showed a very good agreement between outdoor and indoor calibrations except CdS-CdTe and GaAs cells.
- 木更津工業高等専門学校の論文
著者
-
佐々木 誠
函館工業高等専門学校電気電子工学科
-
鈴木 守
木更津工業高等専門学校電気工学科
-
佐々木 誠
日本電信電話株式会社
-
横山 俊義
日本電気株式会社
-
宮澤 一広
木更津工業高等専門学校電気工学科学生
-
吉崎 静男
木更津工業高等専門学校電気工学科
関連論文
- 回転刺激をうけた孵卵後期のニワトリ胚における心拍ゆらぎ解析
- 微小重力刺激をうけた艀卵後期の鶏胚における心拍ゆらぎ解析
- 標準太陽電池の効率測定について
- 標準太陽電池の屋外校正
- 大気の混濁係数と可降水量の測定 -太陽直達光の分光放射測定の一応用-
- シールドマシン用カッタービットのろう付層の非破壊評価