ジャイロトロン周波数、ボディ冷却水温とビーム電流の関係について
スポンサーリンク
概要
- 論文の詳細を見る
Frequency fluctuations of the gyrotron in free-running mode is recommended to be as small as possible for the future active frequency stabilization. As the first step, the characteristics of frequency in free-running mode has been measured ad the slow frequency fluctuation has been already reported. Here the relations among the frequency, the temperature of the cooling water and the beam current are simultaneously measured. The result show that the frequency fluctuation is well related to that of the water temperature at the outlet from the gyrotron. So the chilling facility is added to the water cooling system. Then the frequency fluctuation related to the beam current, which could not be found before without chilling facility, has become to be observed. Besides, phase-locking is tried to find what is needed for the future stabilization experiment.
- 福井大学の論文
著者
関連論文
- サブリミ波ジャイロトロンの発振周波数安定化
- ジャイロトロン周波数、ボディ冷却水温とビーム電流の関係について
- 冷却水温制御によるサブリミ波ジャイロトロン出力周波数の安定化
- 9aSQ-1 永久磁石を用いたLarge Orbital Gyrotron(LOG)の開発(プラズマ応用(高電力電磁波発生),領域2)
- 9aSQ-4 ジャイロトロン出力の高安定化によるプラズマ計測用光源の開発(プラズマ応用(高電力電磁波発生),領域2)
- 9aSQ-2 12Tヘリウムフリー超伝導磁石を用いたCWジャイロトロンの開発(プラズマ応用(高電力電磁波発生),領域2)