Spin-valve GMR Sensor with Improved Ferrite core Exciter for Conductive Microbead Detection by Eddy-current Testing Technique
スポンサーリンク
概要
- 論文の詳細を見る
This paper describes the detection of conductive microbead by spin-valve giant magnetoresistance (SV-GMR) with ferrite core exciter base on eddycurrent testing (ECT) technique. The single and row conductive microbead were detected by the proposed ECT probe. The six microbeads were 125, 150, 200, 250, 300 and 360 μm radiuses. The three model of single row was slightly pitched in each row with range from 400 to 1000 μm. The analytical methods were calculated that confirmed the experimental result. The comparison of reference and proposed ECT probe signal variation with signal to noise ratio were expressed. The experimental results show that the proposed ECT can clearly detect both single and row conductive microbead position.
- 社団法人日本磁気学会の論文
- 2007-09-01
著者
-
Iwahara M.
Kanazawa University
-
Yamada S.
Kanazawa University
-
Iwahara M.
Institute Of Nature And Environmental Technology. Kanazawa Univ.
-
Chomsuwan K.
King Mongkut's University Of Technology Thonburi
-
Somsak T.
King Mongkut's University Of Technology Thonburi
-
Iwahara M
Institute Of Nature And Environmental Technology. Kanazawa Univ.
-
Somsak T.
Graduate School of Natural Science and Technology, Institute of Nature and Environmental Technology,
-
Chomsuwan K.
Graduate School of Natural Science and Technology, Institute of Nature and Environmental Technology,
-
Yamada S.
Graduate School of Natural Science and Technology, Institute of Nature and Environmental Technology,
-
Iwahara M.
Graduate School of Natural Science and Technology, Institute of Nature and Environmental Technology,
-
Iwahara M.
Graduate School Of Natural Science And Technology Kanazawa University
-
Yamada S.
Division Of Biological Measurement And Applications Kanazawa University
関連論文
- Enhanced Potency of Anticancer Drug, Bleomycin by ELF Magnetic Fields(Asia-Pacific Symposium on Applied Electromagnetics and Mechanics (APSAEM08))
- Detection of Magnetic Fluid Volume Density with a GMR Sensor
- Investigation of the Quality Inspection of Electroplated Materials Using Planar Type Meander Coils
- Impedance Characteristics of Planar Meander Coil for the Evaluation of Material Properties at Near Surface
- Novel Three Phase Fault Current Limiter Using Permanent Magnet
- Magnetic Losses in Two Types of Magnetic Bearing System Employing Permanent Magnets
- Magnetic losses in two types of magnetic bearing systems employing permanent magnets
- Simulation Studies of Large Scale Magnetic Current Limiter Using Tableau Approach
- Switching Characteristics of Passive Fault Current Limiter Taking into Account Hysteresis of Core for Varying Power Factor of Load
- An Insight Synthesis of Current Limiter based on Passive Magnetic Components
- Transient Solution of a Transformer Core Demagnetization Scheme
- APPLICATIONS OF AUXILIARY DC OR LOW FREQUENCY MMF EXCITATION IN POWER MAGNETIC DEVICES
- Application of Giant Magnetostrictive Actuator in the Generation of Radicals(Asia-Pacific Symposium on Applied Electromagnetics and Mechanics (APSAEM08))
- Novel GMR Sensor for Estimation of Magnetic Nanoparticles inside Minute Cavities(Asia-Pacific Symposium on Applied Electromagnetics and Mechanics (APSAEM08))
- Influence of ELF Magnetic Fields on Anticancer Drug Cisplatin Potency(Asia-Pacific Symposium on Applied Electromagnetics and Mechanics (APSAEM08))
- GMR Sensor Application in Detecting and Estimating Magnetic Fluid Weight Density inside Various Size Tumors
- Estimation of Density of Low-Concentration Magnetic Fluid by a Needle-Type GMR Sensor for Medical Applications
- Harmonics and Interharmonics Estimation of a Passive Magnetic Fault Current Limiter Using Wavelet Transform
- Performance Estimation of a Flux-Concentration Type Linear Induction Motor Using Three-Phase Equivalent Circuit Parameters
- Performance prediction of a flux-concentration type linear induction motor using three-phase equivalent circuit parameters
- Design and Development of a Linear Induction Motor Utilizing the Effect of Flux-Concentration
- Effect of Flux Concentration on the Performance of a Linear Induction Motor
- Effect of flux-concnetration on the performances of linear induction motor
- Application of Giant Magnetoresistance Sensor for Micro Material Detection(Asia-Pacific Symposium on Applied Electromagnetics and Mechanics (APSAEM08))
- Spin-valve GMR Sensor with Improved Ferrite core Exciter for Conductive Microbead Detection by Eddy-current Testing Technique
- Scratch Detection by Eddy-Current Testing with a High Lift-Off Height
- Conductive micro-bead array detection by high-frequency eddy-current testing technique with SV-GMR sensor
- Improvement of the Measurement Characteristics of a Magnetic Bearing Balance System
- PCB Conductor Dimension and Alignment Inspection Using an ECT Probe with an SV-GMR Sensor
- Eddy-Current Model and Detection in a Thick Stainless Steel Plate
- PCB conductor dimension and alignment inspection by using ECT probe with SV-GMR sensor
- Measurement Characteristics of a Magnetic Bearing Balance System
- Numerical and Experimental Study of Eddy-Current Crack Detection in A Thick SUS Plate
- A Repulsive-Type Magnetic Bearing Micro-Mass Measurement System and Measurement of Resolution
- GMR Sensor Utilization for PCB Inspection Based on the Eddy-Current Testing Technique
- The GMR Sensor Utilization for PCB Inspection based on Eddy-Current Testing Technique
- Application of Phase to Image Processing during the Inspection of Printed Circuit Board by Eddy-Current Testing Probe (論文特集号 〔日本応用磁気学会〕第24回学術講演会)
- Application of Phase for Image Processing during Inspection of Printed Circuit Board by Eddy-Current Testing Probe
- Inspection of Printed-Circuit Board by ECT Probe with Solenoid Pickup Coil
- Inspection of printed circuit board by ECT probe with solenoid pick-up coil
- Estimation of Magnetic Properties of Tissue with Magnetic Fluid by SV-GMR Needle Type Probe(Asia-Pacific Symposium on Applied Electromagnetics and Mechanics (APSAEM10))
- Study of Pulsed Voltage Driving Method for Iron Gallium Alloy Magnetostrictive Linear Actuator(Asia-Pacific Symposium on Applied Electromagnetics and Mechanics (APSAEM10))
- 3D Measurement and Visualization Systems of Distributed Magnetic Field Using Tomography Method(Asia-Pacific Symposium on Applied Electromagnetics and Mechanics (APSAEM08))
- Diurnal Variation in the Response of the Mandible to Orthopedic Force
- Loss Consideration of Magnetic Fault Current Limiter(Asia-Pacific Symposium on Applied Electromagnetics and Mechanics (APSAEM08))
- 25aYE-5 Influence of end plate biasing on ion flow and particle transport in the PANTA