非共沸混合冷媒R22+R114の水平な内面溝付き管内における凝縮および蒸発熱伝達
スポンサーリンク
概要
- 論文の詳細を見る
Experimental results of the condensation and evaporation of non-azeotropic refrigerant mixtures of R22 and R114 inside a horizontal tube with internal spiral grooves are presented. The test condenser and evaporator, which are of the same shape, are tube-in-tube counter flow type heat exchangers. The inner tube is made of copper with a geometry as follows: outer diameter 9.52mm, mean wall thickness 0.60mm, mean inner diameter 8.32mm, groove depth 0.15mm, number of grooves 60, lead angle of grooves 30°. Pure refrigerants of R22 and R114 and three kinds of their mixtures containing about 25, 50 and 75% bulk molar fractions of R114 are tested in the range of refrigerant mass flow rate of 30 to 70kg/s, condensing pressure of 3 to 21 bar, and evaporating pressure of 1 to 7 bar. For the condensation and evaporation of pure R22 and R114 and three kinds of their mixtures, axial distributions of refrigerant, tube wall and cooling water temperatures, wall heat flux, heat transfer coefficient and vapor quality are graphically shown. Circumferential distributions of the condenser tube wall temperature are also shown for pure and mixed refrigerants. The local Nusselt numbers for condensation of pure refrigerants R22 and R114 are higher than those predicted from the previous empirical equation for pure refrigerants in a horizontal smooth tube by 40-70% and 50-80%, respectively. The local Nuseelt numbers of the mixtures are lower than those of pure refrigerants, and the magnitude depends on molar fraction and mass flow rate. The average Nusselt numbers for condensation can be correlated well by the following equation: [numerical formula] where <Nu>^^- is the average Nusselt number, f_y is the function of the bulk molar fraction, l is the total condensing length, d_i is the inner diameter of the tube, H is the phase change number, Re_l is the Reynolds number, Pr_L is the Prandtl number and R is the ρ-μ ratio. The local heat transfer coefficients for evaporation of pure refrigerants R22 and R114 are higher than those predicted from the previous empirical equation for a pure refrigerant R22 in a horizontal smooth tube by 120% and 90%, respectively. The local heat transfer coefficients of the mixtures are lower than those of pure refrigerants, and the magnitude depends mainly on molar fraction.
- 九州大学の論文
- 1987-12-28
著者
関連論文
- 報告記 : 2006年度日本冷凍空調学会年次大会
- CO_2/DME混合冷媒を用いたヒートポンプサイクルの性能解析
- 熱交換器における技術展開
- 第44回日本伝熱シンポジウムを終えて
- 海洋温度差発電プラントの設計と制御のための計算機シミュレーションの開発
- 蓄熱体による湯沸器の開発研究
- 高温蓄熱器の基礎的及び応用的研究
- 修正BWR状態方程式による非共沸混合媒体の熱力学的性質の計算
- 高温蓄熱体による湯沸器の開発研究
- クロスフィンチューブ熱交換器におけるフィンカラー形状が伝熱性能に及ぼす影響
- 伝熱管とフィン接触部におけるフィンカラー形状が熱交換器性能に及ぼす影響
- ヘリンボーン溝付管内凝縮熱伝達および圧力損失に及ぼす溝形状の影響
- 報告記 ASHRAE Winter Meeting
- 波流凝縮液膜の流動および熱伝達特性に関する数値解析
- 傾斜面上を表面波を伴って流れる流下液膜の数値計算 : 第3報, 傾斜角および表面張力の影響
- 傾斜面上を表面波を伴って流れる流下液膜の数値計算 : 第2報, 流動および熱伝達特性に及ぼす表面波の影響〔熱工学, 内燃機関, 動力など〕
- 傾斜面上を表面波を伴って流れる流下液膜の数値計算 : 第1報, 気液界面条件の取扱い方法に関する考察〔流体工学, 流体機械〕
- フロン問題の現状について
- 管径と質量速度を考慮した管内二相流摩擦損失の予測式の作成(次世代冷凍空調システムと要素技術 OS.3)
- 1.伝熱促進技術の研究・開発動向 1.2凝縮熱伝達
- 非共沸混合冷媒ヒートポンプサイクルの性能予測
- 非共沸混合冷媒R22+R114の水平管内強制沸騰熱伝達
- 非共沸混合冷媒R22+R114の水平管内凝縮
- 非共沸混合冷媒R22+R114の水平な内面溝付き管内における凝縮および蒸発熱伝達
- ASHRAE Annual Conference
- C-18 室内気流分布の数値計算および模型実験