静電分離に関する研究IV 傾斜帯電電極に接触した粉体の運動について
スポンサーリンク
概要
- 論文の詳細を見る
This report is on some experimental results as to how particle moves when it touches the high voltage electrode. This experiment has made the principle of the inclined-plane-electrode electrostatic separator, which we have developed, clearer and more accurate. The conclusion is that the following conditions are most appropriate. 1. Particle falling rate from the hopper is 8-10 g/min/4 x 250mm^2. 2. The most suitable size of the particle is 100-150 mesh or 150-200 mesh. 3. The inclination of the plane electrode is about 60 degrees. 4. The distance between the lower end of the inclined-plane-electrode and the receiving equipment is about 15 cm. 5. The distance between the net of the hopper and the inclined-plane-electrode is about 6 cm. 6. The applied voltage is negative polarity. 7. The applied voltage to a good conductor like a curbon is about 10 KV. 8. The location of the inclined-plane-electrode where the particle fall from the hopper is about 4.5 cm far from its lower end.
- 山形大学の論文
- 1968-01-20
著者
関連論文
- 緩波頭衝撃電圧で模擬された開閉サージ の基礎研究
- 試験用変圧器を用いた開閉インパルスの発生とその応用
- 試験の採点と成績処理システム
- 開閉インパルスの発生とその放電特性
- 緩波頭衝撃電圧による短ギャップの放電特性
- 不平等電界における単発商用周波電圧のフラッシーバ特性
- 気中ギャップにおける単発商用周波電圧のフラッシオーバ特性
- 交さ円筒導体ギャップにおける放電現象(III)
- 静電分離に関する研究VI 傾斜帯電電極式静電選鉱装置の分離機構
- 静電分離に関する研究V 粉体の見かけの固有抵抗について
- 静電分離に関する研究IV 傾斜帯電電極に接触した粉体の運動について