Wide-Dynamic-Range Digital-Pixel CMOS Image Sensor Applying New Readout Operation (Electronic Circuits)
スポンサーリンク
概要
- 論文の詳細を見る
A new wide-dynamic-range CMOS image sensor with pixel-level analog-to-digital (A/D) converters is proposed. The pulse-counters in the sensor are arranged outside the pixel area in order to reduce pixel size, which is a key requirement for making high-definition cameras. A new scheme called variable threshold operation is also presented as a suitable readout operation method for the sensor. Experimental measurements on a prototype sensor show that the prototype can obtain linear output response proportional to illumination by applying the new readout operation.
- 社団法人電子情報通信学会の論文
- 2006-02-01
著者
-
OHTAKE Hiroshi
NHK Science & Technical Research Laboratories
-
Kawai T
Electron Tube Division #2 Hamamatsu Photonics K. K.
-
TANIOKA Kenkichi
NHK Science and Technical Research Laboratories
-
Takayama K
Tohoku University Biomedical Engineering Research Organization
-
Goto Masahide
Nhk Science And Technology Research Laboratories
-
Goto Masahide
Nhk Science And Technical Research Laboratories
-
Ohtake Hiroshi
Nhk Science And Technical Research Laboratories
-
EGAMI Norifumi
NHK Science & Technical Research Laboratories
-
Egami Norifumi
Nhk Science And Technology Research Laboratories
-
Abe Masahide
Hiroshima International University
-
Tanioka K
Nhk Science And Technical Research Laboratories
-
Tanioka Kenkichi
Nhk Science And Technical Research Lab's
-
WATABE Toshihisa
NHK Science and Technology Research Laboratories
-
Tanoi Keitaro
Graduate School Of Agricultural And Life Sciences The University Of Tokyo
-
Watabe Toshihisa
Nhk Science And Technical Research Laboratories
関連論文
- X-ray Spectra from Weakly Ionized Linear Copper Plasma
- 酸化亜鉛TFTを信号読出し回路に用いた有機膜積層型撮像デバイス(高機能イメージセンサとその応用)
- PJ-535 Predictors for Sirolimus-Eluting Stent Restenosis Using Pressure Wire, Coronary Angiography, and IVUS Parameters(PJ090,Coronary Circulation/Chronic Coronary Disease (Basic/Clinical) (IHD),Poster Session (Japanese),The 73rd Annual Scientific Meeting
- PE-029 Influence of Coronary Plaque Characteristics in LMCA between Metabolic and Non-Metabolic Syndrome Subjects : A Volumetric IVUS Study(PE005,Metabolic Syndrome 1 (H),Poster Session (English),The 73rd Annual Scientific Meeting of The Japanese Circulat
- OJ-003 Prevention of In-stent Neointimal Proliferation by Pioglitazone Study(POPPS)(Coronary revascularization, PCI(05)(IHD),Oral Presentation(Japanese),The 72nd Annual Scientific Meeting of the Japanese Circulation Society)
- PJ-748 Relationship between High Sensitivity C-Reactive Protein and In-stent Restenosis after Sirolimus-eluting Stent Implantation(Coronary revascularization, PCI-21, The 71st Annual Scientific Meeting of the Japanese Circulation Society)
- X-ray Spectra from a Brass-target Plasma Triode
- Enhanced K-edge Angiography Utilizing Tantalum Plasma X-ray Generator in Conjunction with Gadolinium-Based Contrast Media
- Variations in Cerium X-ray Spectra and Enhanced K-Edge Angiography
- Inhomogeneous Vasodilatory Responses of Rat Tail Arteries to Heat Stress : Evaluation by Synchrotron Radiation Microangiography
- C-reactive protein predicts non-target lesion revascularization and cardiac events following percutaneous coronary intervention in patients with angina pectoris
- Quantitative measurement of mitral valve coaptation in functional mitral regurgitation : In vivo experimental study by real-time three-dimensional echocardiography
- PJ-339 Association of Coronary Plaque Characteristics by Virtual HistologyTM Intravascular Ultrasound and Coronary Temperature(Intravascular endoscopy/Intravascular ultrasound(06)(I),Poster Session(Japanese),The 72nd Annual Scientific Meeting of the Japan
- PJ-010 Assessment of Cell Density in the Fibrous Cap by Optical Coherence Tomography(Acute myocardial infarction, clinical(diagnosis/treatment)(08)(IHD),Poster Session(Japanese),The 72nd Annual Scientific Meeting of the Japanese Circulation Society)
- OE-253 Natural History of the Thin-Cap Fibroatheroma Assessed by Optical Coherence Tomography in Vivo(Coronary revascularization, PCI(02)(IHD),Oral Presentation(English),The 72nd Annual Scientific Meeting of the Japanese Circulation Society)
- Measurement of Cerium X-ray Spectra Using a Cerium Oxide Powder Filter and Enhanced K-edge Angiography
- X-ray Spectra from a Characteristic X-ray Generator with a Molybdenum Tube
- Quasi-Monochromatic X-Ray Generator Utilizing Graphite Cathode Diode with Transmission-Type Molybdenum Target
- Quasi-Monochromatic Flash X-Ray Generator Utilizing Disk-Cathode Molybdenum Tube
- Monochromatic polycapillary imaging utilizing a computed radiography system
- Intense Characteristic X-ray Irradiation from Weakly Ionized Linear Plasma and Applications
- Irradiation of intense characteristic x-rays from weakly ionized linear molybdenum plasma
- PJ-819 The Usefullness of Hyperemic Trans-Stent Gradient for the Prediction of Restenosis following Sirolims-Eluting Stents Implantation(Coronary revascularization, PCI(26)(IHD),Poster Session(Japanese),The 72nd Annual Scientific Meeting of the Japanese C
- X-ray Enhancement by Fuorescent Emission using the Plasma X-ray Source
- Water-Window X-ray Source Driven by an Ignitron Pulser
- A simple measurement of the pH of root apoplast by the fluorescence ratio method
- Influence of Mercury on Soybean Plants (Glycine max L.) at Low pH
- An Aluminum Influence on Root Circumnutation in Dark Revealed by a New Super-HARP (High-gain Avalanche Rushing Amorphous Photoconductor) Camera
- OJ-017 Relationship between the Change of Fibrous Cap Thickness and Plaque Morphology : Six Months Follow-up Study of Optical Coherence Tomography(OJ03,Intravascular Imagings (I),Oral Presentation (Japanese),The 73rd Annual Scientific Meeting of The Japan
- 6 Quantification of the Target Lesion Calcification by Optical Coherence Tomography : A Validation Study and Its Impact on Stent Expansion(Frontiers in Coronary Imaging,Symposium 15 (SY-15) (A),The 73rd Annual Scientific Meeting of The Japanese Circulatio
- OJ-178 VH-IVUS Analysis of Renal Artery Lesions with Atherosclerotic Renal Artery Stenosis(Intravascular endoscopy / Intravascular ultrasound(02)(I),Oral Presentation (Japanese),The 72nd Annual Scientific Meeting of the Japanese Circulation Society)
- PE-246 Obesity, Dyslipidemia and Constrictive Remodeling are Characteristic of Young Patients with Acute Myocardial Infarction(Acute myocardial infarction, clinical(pathophysiology)(02)(IHD),Poster Session(English),The 72nd Annual Scientific Meeting of th
- PE-195 Impact of Body Mass Index and Framingham Risk Score on Coronary Atherosclerotic Disease(Atherosclerosis, clinical-04, The 71st Annual Scientific Meeting of the Japanese Circulation Society)
- Rhizosphere pH Profile of Rice Plant Influenced by Al Treatment
- Analysis of Potassium Uptake by Rice Roots Treated with Aluminum Using a Positron Emitting Nuclide, ^K
- PE-273 Dynamics of Mitral Complex Geometry during Acute Left Ventricular Pressure Overload : In Vivo Experimental Study by Using Real-time 3D Echocardiography(Valvular heart disease/Pericarditis/Cardiac tumor-2, The 71st Annual Scientific Meeting of the J
- PJ-788 Evaluation of Coronary Endothelial Function in High-fat Dietinduced Obese Dogs by Using Catheter-type No Sensor(Endothelium-4, The 71st Annual Scientific Meeting of the Japanese Circulation Society)
- Photoconductive Properties of Organic Films Based on Porphine Complex Evaluated with Image Pickup Tubes
- Ultra-High-Sensitivity New Super-HARP Pickup Tube and Its Camera(Recent Progress in Photon Detection Technology)
- Image Pickup from Zinc Phthalocyanine/Bathocuproine Double-Layer Film Using Pickup Tube
- An analysis of long-distance water transport in the soybean stem using H2[15]O
- 128×96 Pixel FEA Image Sensor with HARP Target(Special Issue on Electronic Displays)
- SS-9 SUPER-HARP : AN ULTRA-HIGH SENSITIVE CAMERA TUBE WITH AN AVALANCHE MODE PHOTOCONDUCTIVE TARGET
- Lag Characteristics of Flat Image Sensor Consisting of Field Emitter Array and High-Gain Avalanche Rushing Amorphous Photoconductor Target
- Studies On Ionization Coefficients of Targets in an Amorphous Selenium APD for Pick-up Tubes by New Type Least Squares
- An Analysis of Long-Distance Water Transport in the Soybean Stem Using H_2^O
- Aluminum distribution and the condition of the plasma membrane in cultured tobacco cells detected using staining methods
- Wide-Dynamic-Range Digital-Pixel CMOS Image Sensor Applying New Readout Operation (Electronic Circuits)
- A $128\times 96$ Pixel Stack-Type Color Image Sensor: Stack of Individual Blue-, Green-, and Red-Sensitive Organic Photoconductive Films Integrated with a ZnO Thin Film Transistor Readout Circuit
- Coronary microvascular endothelial function deteriorates late (12 months) after sirolimus-eluting stent implantation
- Improvement in Photoconductive Properties of Coumarin 30-Evaporated Film by Fullerene Doping for Blue-Sensitive Photoconductors
- Color Sensors with Three Vertically Stacked Organic Photodetectors
- Photoconductive Properties of Organic Films Based on Porphine Complex Evaluated with Image Pickup Tubes
- Soft X-ray Charging Method for a Silicon Electret Condenser Microphone
- Detailed Observation of Arterial Healing after Stent Implantation in Swine Arteries by Using Optical Coherence Tomography
- A 128×96 Pixel, 50 m Pixel Pitch Transparent Readout Circuit Using Amorphous InGaZnO Thin-Film Transistor Array with IndiumTin Oxide Electrodes for an Organic Image Sensor
- Dependence of Thickness on Avalanche Characteristics of Te-Doped Amorphous Selenium Photoconductive Target
- Radioactive cesium flow in Rhus vernicifera(Plant nutrition)
- Image Pickup from Zinc Phthalocyanine/Bathocuproine Double-Layer Film Using Pickup Tube
- Analyses of Noise in a Highly Sensitive Image Device
- Different magnesium uptake and transport activity along the rice root axis revealed by ^Mg tracer experiments(Plant nutrition)
- Evolution of Ultra-High-Speed CCD Imagers